Functions, Menus and Parameters

The following is a list of all of the main functions that the application has to contain as well as their control
parameters.
The name, user type, default, unit of measurement, limits, and access modes are given for each parameter.
Access is indicated as follows:
ERWZ
| | | |______ Writeable only with drive disabled
| | |________ Writeable
| |_________ Readable
|___________ Access in Expert mode

5.1 MAIN Menu

The MAIN menu contains some basic settings for the electric line shaft and operating state monitors
Parameter Name
11000 Els Control Mode
Selector for electric line shaft function control mode.
In Phase mode (active by default), the system follows reference master speed with the selected ratio, maintaining the
phase angle. In Follower mode, the system follows reference master speed with the selected ratio, but without controlling
the phase angle.
11002 Els Appl Enable src
Selector for source of application activation/deactivation command (always active by default).
By means of a digital input or decomp word command, you can control activation/deactivation of the application in order
to use, as an alternative, the drive system functions (for example, potentiometer motor).
Even if the electric line shaft function is deactivated, the virtual master function (if programmed) stays active,
guaranteeing the chain of references to other drives.
11006 Els FastS src
Selector for source of immediate stop command (function not active by default). Active at low level, starts fast stop
sequence defined by parameter Els FastS behavior.
11008 Els FastS behaviour
Selector for fast stop mode run on low level of reference input Els FastS src:
Disable (default): torque to motor is immediately eliminated
FS: stop ramp to speed zero defined by parameter Els FastS Dec Time with maintenance of torque applied
to motor
FS & Dis: stop ramp to speed zero defined by parameter Els FastS Dec Time with maintenance of torque to
motor until speed zero signal (IPA 942 Speed 0 delay)
11010 Els FastS Dec Time
Fast stop ramp to speed zero.
Corresponds to the time needed to decelerate from the speed set in parameter Speed ref top lim (IPA 670 on
REFERENCES menu) to 0.
11060 Els Enabled dest
Selector for destination of Els Enabled mon monitor.
User Guide Electrical Line Shaft for ADV200
User type
Value
Enumerative
Phase (def)
Follower
Enumerative
One (def)
Dig inp x
Decomp
Dig inp x X
Enumerative
One (def)
Dig inp x
Decomp
Dig inp x X
Enumerative
Disable (def)
FS
FS & Dis
Float
0.10
Enumerative
Null (def)
Pad from 1 to 16
_____
Unit
-
-
-
-
s
-
_
Min
Max
Access
-
-
RWZ
-
-
ERWZ
-
-
ERWZ
-
-
ERWZ
0.01
10
ERW
-
-
ERWZ
Page 11 of 72