8.2.3 Changing values

Note !
Flashing points and characters in grey.
Changing integer numerical values
Press Enter to access "Edit" mode.
The first digit on the right starts flashing, which means the value can be changed using the up and down arrow keys.
When you press Enter again, the next digit on the left flashes; if the digit is the last in the window, the display moves to
the next window.
Pressing Enter on the last digit saves the value.
Press Enter and hold down to save the parameter even if it is not the last digit of the parameter.
Press Prg to exit the "Edit" mode without saving the parameter.
E.g.:
Synchronous list, Menu 5.3 – LIFT SEQUENCES, PAR 11062 Cont close delay (default = 200 ms)
0 5
.8 8.
0 2 .0
.
0.
00
.
0
0
.
0 5
.8 8.
0 2 .0
.
0.
Changing Float numerical values
When a float parameter is selected, the integer part is displayed first with a fixed point on the right indicating that the
number continues with the decimal part.
If you press Enter in this state, only the integer part is changed.
To modify the decimal part as well, first display the bottom window by pressing the down arrow key, then press Enter to
modify the number from the decimal part.
Press Prg to exit the "Edit" mode without saving the parameter.
E.g.:
Synchronous list, Menu 5.2 – RAMPS, PAR 11040 Acc ini Jerk (default = 0.50 m/s
0 5
.8 8.
05
Enter
70
20. 02.
88.
Enter
Enter
10
.
6 6
.
Enter
(x5)
Enter
05.03
.
Enter
(x3)
Enter
0 2.0
.5.
Enter
(x5)
Enter
00. 0
0.
00.
Enter
Enter
05.03
.
Enter
(x3)
Enter
0 2.0
.5.
Enter
(x5)
Enter ( > 2 sec)
05.02.
Enter
Enter
.
0
0.
0 8.
00.
(x3)
Enter ( > 2 sec)
ADL300 • Quick installation guide - Specifications and connection
22.
the flashing point of the second digit from the left displays the middle window
88.
8.1
.
1
0. 62.
82 .0
Enter
02.
0.
5.
02.
0 .5
Enter
00.
00
.
0 0
.
Enter
Enter
1
0.
6
2.
82 .0
Enter
02 .0
.
5.
1
0. 40.
0 0
.
8
0 .
Enter
0 0
.
80 .
.
0.
Enter
.
02 .0 .5
.
Enter
Enter
0
0. 00
.
0 0
. 0
0.
Enter
.
0.
Enter
)
3
05.
0 0
.
0
5
.
0
Enter
08
.
0
0.
0
2 .0
.5.
Enter
0.
05.
0 0.
Enter