Error Messages When Modifying A Parameter; Displaying And Closing Messages - gefran installationSIEIDrive ADL300 Quick Start Up Manual, Specification And Installation

Vector inverter for lifts with ynchronous/asynchronous motors
Table of Contents

Advertisement

Modifying Enum values
When you press Enter on an Enum value, the first digit on the right flashes.
Use the arrow keys to scroll all the enum values of that parameter cyclically.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 5.3 – LIFT SEQUENCES, PAR 11060 Sequence start mode (default = [0] Start forward/reverse)
05
.88.
Enter
Modifying Link values
When you press Enter on a Link value, the first digit on the right flashes.
Use the arrow keys to scroll all the links in the list associated with that parameter cyclically.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 11 – DIGITAL OUTPUTS, PAR 1410 Dig output 1X src (default = [1062] Drive OK)
1 1.
8 8.
Enter
Modifying On-Off values
Boolean values are displayed with the words On and Off.
When you press Enter, the first digit on the right flashes.
Use the up and down arrow keys to change the value cyclically from On to Off.
Press Enter again to accept the value.
Press Prg to reject the value and restore the previous value.
E.g.:
Synchronous list, Menu 5.5 – DISTANCE, PAR 11138 Out floor function (default = [0] OFF)
05
.88.
Enter

8.2.4 Error messages when modifying a parameter

When accepting a value, if you hold Enter down or press Enter on the last digit, an error message may be displayed:
RO
Read only parameter, if Enter is pressed on a read only parameter
ORNG
Value outside range
DRVE
Drive enabled, if you are trying to modify a parameter than cannot be modified with the drive enabled
ERR
Other errors
Press Prg to clear the error message.

8.2.5 Displaying and closing Messages

Note !
Some messages may be displayed on the integrated keypad at start-up or during operation. The list of messages is provided in chapter "10.3 Messages" .
Sub-codes are not shown on the integrated keypad.
Press Prg to exit a message if it does not close automatically.
0 5.03
.
10. 60.
(x3)
Enter
1
4. 10.
1
0. 62.
Enter
Enter
0
5.05.
(x4)
Enter (x11)
ADL300 • Quick installation guide - Specifications and connection
0 0.
80
.
0 0
Enter
Enter
10
.
6
2.
10
.
6
4.
Enter
1 1
.
3 8
8
. FF.
o
Enter
Enter
.
00
.
00
.
01
.
Enter
10
. 64.
8
.
.
8 8
.o
FF
n.
o
0 0 . 81.
71

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sieidrive adl300Sieidrive adl300 advancedSieidrive adl300 basicSieidrive adl300aSieidrive adl300b

Table of Contents