4 - Specification

4.1 Environmental Conditions

Installation location �������������������� Pollution degree 2 or lower (free from direct sunligth, vibration, dust, corrosive or
Installation altitude �������������������� Max 2000m (6562 feet) above sea level. With 1.2% reduction in output current for every
Mechanical conditions for installation ����� Vibrational stress: EN 60721-3-3 Class 3M1
Operating temperature ����������������� -10...+45°C (32°...113°F)
Operating temperature ����������������� +45 ... +50°C (+113 ... +122°F) with 1% derating every °C starting from 45°C and up to
Air humidity (operating) ����������������� from 5 % to 85 % and from 1 g/m
Air pressure (operating) [kPa] ������������ from 70 to 106

4.2 Standards

Climatic conditions �������������������� EN 60721-3-3
Electrical safety ����������������������� EN 50178, EN 61800-5-1, UL508C, UL840 degree of pollution 2
Vibration ����������������������������� Class 3M1 EN 60721-3-3
EMC compatibility ��������������������� EN 12015
Protection degree���������������������� IP20
Approvals ����������������������������
EC Directive �������������������������� LVD 2014/35/EU, EMC 2014/30/EU, Lift 2014/33/EU, RoHS 2011/65/EU

4.3 Precision

4.3.1 Speed control

Speed control precision ������������������ Flux vector CL control with feedback and brushless: 0.01 % motor rated speed

4.3.2 Speed control limits

Speed range (*) ������������������������ ± 32000 rpm
Speed format (*) ����������������������� 32 bit
Frequency range ����������������������� ± 2000 Hz
Max frequency ������������������������ Flux vector CL control with feedback and brushless: 300Hz, FVOL: 150 Hz, VF: 600 Hz
Min frequency ������������������������ 0 Hz
(*) referred to Full scale speed, PAR:680.

4.3.3 Torque control

Torque resolution (*) �������������������� > 0.1 %
Torque control precision (*) ��������������� Flux vector CL with feedback: ± 5%
Direct torque control �������������������� yes
Current limitation ����������������������� Limits ±, Mot/gen limits, Variable limits
(*) referred to rated torque

4.3.4 Current rating

Overload ����������������������������� 200% (sizes 4 and 5 = 180%) *10 sec with output frequency more than 3 Hz
Switching frequency �������������������� 10 kHz
16
inflammable gases, fog, vapour oil and dripped water, avoid saline environment)
100 m starting from 1000 m.
50°C. Operation at temperatures of > 50°C is not allowed
,
Flux vector OL control: ± 30 % rated slip of motor
SSC control: ± 60 % rated slip of motor
150% with output frequency less than 3 Hz.
ADL300 • Quick installation guide - Specifications and connection
to 25 g/m
with no humidity (or condensation)
3
3
(ADL300-...-2M series with optional external filter)