Scanning Of The Parameters - gefran ADL300 Installations

Vector inverter for lifts with asynchronous/synchronous motors
Table of Contents

Advertisement

(4)
Depends on the type of parameter:
Numeric parameter: displays the numeric value of the parameter, in the format required, and unit of measurement.
Binary selection: the parameter may assume only 2 states, indicated as On - Off or 0 - 1.
LINK type parameter: displays the description of the parameter set from the selection list.
ENUM type parameter: displays the description of the selection
Command: displays the method of execution of the command
(5)
Parameter number
(6)
In this position, the following may be displayed:
Numeric parameter: displays the default, minimum and maximum values of the parameter. These values are displayed in sequence pressing the ► key.
LINK type parameter: displays the number (PAR) of the parameter set.
ENUM type parameter: displays the numeric value corresponding to the current selection.
Command: in the case of an error in the command, indicates that ESC must be pressed to terminate the command.
Messages and error conditions:
Param read only
Password active
Drive enabled
Input value too high
Input value too low
Out of range
5.2.3

Scanning of the parameters

ADL300 - Fast installations and commissioning
attempt to modify a read-only parameter
the parameter protection password is active
attempt to modify a non-modifiable parameter with the drive enabled
the value entered too high
the value entered too low
attempt to insert a value outside the min. and max. limits
Pag. 27 of 52