Asynchronous Motor Startup Wizard (With The Optional Keypad) - gefran installationSIEIDrive ADL300 Quick Start Up Manual, Specification And Installation

Vector inverter for lifts with ynchronous/asynchronous motors
Table of Contents

Advertisement

9.1 Asynchronous motor startup wizard (with the optional keypad)

The ADL300 can operate with regulation modes: Voltage/Frequency (SSC) , Sensorless (open loop) and field-oriented
vector control (closed loop).
Note!
Before starting, check the factory settings:
Menu 02 DRIVE INFO, parameter 02.2 Control type, PAR: 480, default=11.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Menu 04 DRIVE CONFIG, parameter 04.2 Regulation mode, PAR: 552, default=SSC control.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
The STARTUP WIZARD is a guided procedure used for quick start-up of the drive that helps to set the main
parameters.
It consists of a series of questions, relating to the various sequences for entering and calculating the parameters
necessary for correct drive and lift application operation. The order of these sequences is as follows:
Electrical connections
Setting motor parameters
Autotune with motor at stand-still or coupled to the load
Setting encoder parameters (with control mode=Flux vector CL)
Setting the maximum speed reference and maximum system speed
Setting system weights
Setting application parameters
Saving parameters
The format of the function selection page is as follows:
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Pressing the E key, the function to be programmed is accessed.
Press the ▼ (Down) key to move to the next function skipping the current function.
Press the ▲ (Up) key to return to the previous function.
To terminate the sequence of functions and return to the menu, press the ESC key.
The end of the start-up sequence is indicated with the page:
03 STARTUP WIZARD
End of se q uence!
Up=Back
Press the ▼(Down) key to exit the sequence and return to the menu.
88
02 DRIVE INFO
2/26
Control type
Asynchronous
Value: 11
04 DRIVE CONFIG
2/19
 
x1
Regulation mode
Value: 0
03 STARTUP WIZARD
Set motor data?
E=Yes
Down=Exit
ADL300 • Quick installation guide - Specifications and connection
PAR:
480
PAR:
552
SSC control
Down=Next
See step 1
See step 2
See step 3
See step 4
See step 6
See step 7
See step 8
See step 9

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sieidrive adl300Sieidrive adl300 advancedSieidrive adl300 basicSieidrive adl300aSieidrive adl300b

Table of Contents