8.2.6 Displaying and resetting Alarms

Note !
The alarms are shown on the display of the integrated keypad with the abbreviated text shown in brackets "[XXX]" in chapter "10.1 Alarms" on page 88 .
Active alarms are displayed by a flashing indicator.
Alarms that have been removed but not yet reset are fixed.
If there is more than one alarm, these can be displayed using the up and down arrow keys.
Press Prg to exit the alarm display mode.
To reset an alarm, press the up and down arrow keys together.
To display the sub-codes, press Enter:
E.g.:
PL C E
Index
Error message shown on
the display [on the inte-
47

8.2.6.1 Alarm Log

Enter menu 22 - ALARM LOG to display the list of alarms
Use the arrow keys to scroll the list with the abbreviations shown in chapter 10.1.
Press Enter to display the alarm code.

8.2.7 Startup wizard

Enter Menu 3 - STARTUP WIZARD to scroll the list of operations, which are abbreviated as follows:
Operations displayed on the optional keypad
Press Enter to enter the selected operation.
At this point, the list of associated parameters that must be modified as described previously is displayed.
Motor self-tuning is described below.
Press the down arrow to move on to the next operation.
Press the up arrow to return to the previous operation.
Press Prg to abort the STARTUP WIZARD sequence.
Note !
The STARTUP WIZARD cannot run simultaneously on the two keypads (integrated and optional).
When running on one, it cannot be accessed from the other.
Note !
For further information see chapters "9.1 Asynchronous motor startup wizard" on page 81 and "9.2 Startup wizard for brushless motors on page 93 .
72
00.
01
.
Enter
Prg
Sub-code
grated keypad]
Condition: may occur during loading of the Mdplc application
Error config plc [PLCE]
The Mdplc application present on the drive is not run.
0004H-4
Set motor data?
Run autotune still?
Set encoder param?
Set max motor speed?
Set max car speed?
Set system weights?
Set application par?
Save parameters?
End of sequence!
ADL300 • Quick installation guide - Specifications and connection
The application downloaded has a different Crc on DataBlock and Function table
Operations displayed on the integrated keypad
MOT
STIL
ENC
MSPD
CSPD
WEIG
LIFT
SAVE
END