Speed Fbk Loss Alarm According To The Type Of Feedback - gefran installationSIEIDrive ADL300 Quick Start Up Manual, Specification And Installation

Vector inverter for lifts with ynchronous/asynchronous motors
Table of Contents

Advertisement

10.2 Speed fbk loss alarm according to the type of feedback

Note !
For the correct interpretation of the cause of the alarm trigger, it is necessary to transform the hex code indicated in parameter 15.13 SpdFbkLoss code,
PAR 2172 , in the corresponding binary and verify in the encoder table that the active bits and related description are used.
Example with encoder Endat:
PAR 2172 = A0H
In the table "Speed fbk loss [22] alarm with absolute encoder EnDat" A0 is not indicated in the value column.
A0 should be contemplated as a bitword with meaning A0 -> 10100000 -> bit 5 and bit 7 . The following causes simultaneously intervene:
- Bit 5 = 20H Cause: the SSI signal interferences cause an error in the CKS or parity.
- Bit 7 = 80H Cause: The encoder has detected an incorrect operation and communicates it to the converter through the Error bit. Bits 16..31 present the
type of incorrect encoder operation detected.
The value is displayed in hexadecimal format on the optional and standard keypad.
Speed fbk loss [22] alarm with digital incremental encoder
Bit
Value
Name
0
0x01
CHA
Cause: no impulses or disturbance on incremental channel A.
Solution: Check the connection of the encoder-drive channel A, check the connection of the screen, check the encoder supply voltage, check parameter
2102 Encoder supply, check parameter 2104 Encoder input config.
1
0x02
CHB
Cause: no impulses or disturbance on incremental channel B.
Solution: Check the connection of the encoder-drive channel B, check the connection of the screen, check the encoder supply voltage, check parameter
2102 Encoder supply, check parameter 2104 Encoder input config.
2
0x04
CHZ
Cause: no impulses or disturbance on incremental channel Z.
Solution: Check the connection of the encoder-drive channel Z, check the connection of the screen, check the encoder supply voltage, check parameter
2102 Encoder supply, check parameter 2104 Encoder input config, check parameter 2110 Encoder signal check
Speed fbk loss [22] alarm with sinusoidal incremental encoder
Bit
Value
Name
3
0x08
MOD_INCR
Cause: voltage level not correct or disturbance on signals of incremental channels A-B.
Solution: Check the connection of the encoder-drive channels A-B, check the connection of the screen, check the encoder supply voltage, check
parameter 2102 Encoder supply, check parameter 2108 Encoder signal Vpp.
Speed fbk loss [22] alarm with SinCos encoder
Bit
Value
Name
3
0x08
MOD_INCR
Cause: voltage level not correct or disturbance on signals of incremental channels A-B.
Solution: Check the connection of the the encoder-drive channels A-B, check the connection of the screen, check the encoder supply voltage, check
parameter 2102 Encoder supply, check parameter 2108 Encoder signal Vpp.
4
0x10
MOD_ABS
Cause: voltage level not correct or disturbance on signals of absolute SinCos channels.
Solution: Check the connection of the the encoder-drive channels A-B, check the connection of the screen, check the encoder supply voltage, check
parameter 2102 Encoder supply, check parameter 2108 Encoder signal Vpp.
Speed fbk loss [22] alarm with SSI absolute encoder
Bit
Value
Name
3
0x08
MOD_INCR
Cause: voltage level not correct or disturbance on signals of incremental channels A-B.
Solution: Check the connection of the the encoder-drive channels A-B, check the connection of the screen, check the encoder supply voltage, check
parameter 2102 Encoder supply, check parameter 2108 Encoder signal Vpp.
5
0x20
CRC_CKS_P
Cause: SSI signals not present or disturbed.
Solution: Check the connection of the clock and encoder-drive data, check the connection of the screen, check the encoder supply voltage, check param-
eter 2102 Encoder supply, check parameter 2112 Encoder SSI bits.
8
0x100
Setup error
Cause: An error occurred during setup.
Solution: Check the connection of the clock and encoder-drive data, check the connection of the screen, check the encoder supply voltage, check
parameter 2102 Encoder supply, check parameter 2112 Encoder SSI bits.
(hex value)
ADL300 • Quick installation guide - Specifications and connection
Description
Description
Description
Description
111

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sieidrive adl300Sieidrive adl300 advancedSieidrive adl300 basicSieidrive adl300aSieidrive adl300b