9.2 Startup wizard for brushless motors (with the optional keypad)

The ADL300 can operate with regulation modes: field-oriented vector control of permanent magnet synchronous mo-
tors (brushless).
Note!
Before starting, check the factory setting:
Menu 02 DRIVE INFO, parameter 02.2 Control type, PAR: 480, default=12.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Menu 04 DRIVE CONFIG, parameter 04.2 Regulation mode, PAR: 552, default=Flux vector CL.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
The STARTUP WIZARD is a guided procedure used for quick start-up of the drive that helps to set the main
parameters.
It consists of a series of questions, relating to the various sequences for entering and calculating the parameters
necessary for correct drive and lift application operation. The order of these sequences is as follows:
Electrical connections
Setting motor parameters
Autotune with motor at stand-still or coupled to the load
Setting encoder parameters
Encoder phasing
Setting the maximum speed reference and maximum system speed
Setting system weights
Setting application parameters
Saving parameters
The format of the function selection page is as follows:
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Pressing the E key, the function to be programmed is accessed.
Press the ▼ (Down) key to move to the next function skipping the current function.
Press the ▲ (Up) key to return to the previous function.
To terminate the sequence of functions and return to the menu, press the ESC key.
The end of the start-up sequence is indicated with the page:
03 STARTUP WIZARD
End of se q uence!
Up=Back
Press the ▼(Down) key to exit the sequence and return to the menu.
100
02 DRIVE INFO
2/26
Control type
Synchronous
Value:
04 DRIVE CONFIG
2/19
 
x1
Regulation mode
Value: 2
03 STARTUP WIZARD
Set motor data?
E=Yes
Down=Exit
ADL300 • Quick installation guide - Specifications and connection
PAR:
480
12
PAR:
552
Flux vector CL
Down=Next
See step 1
See step 2
See step 3
See step 4
See step 5
See step 6
See step 7
See step 8
See step 9

Hide quick links: