9.1 Asynchronous motor startup wizard (with the integrated keypad)
The ADL300 can operate with regulation modes: Voltage/Frequency (SSC) , Sensorless (open loop) and field-oriented
vector control (closed loop).
Note!
Before starting, check the factory settings:
Menu 02 DRIVE INFO, parameter 02.2 Control type, PAR: 480, default=11.
0 2
.88.
Enter
Menu 04 DRIVE CONFIG, parameter 04.2 Regulation mode, PAR: 552, default=SSC control.
0 4
.88.
Enter
The STARTUP WIZARD is a guided procedure used for quick start-up of the drive that helps to set the main
parameters.
It consists of a series of questions, relating to the various sequences for entering and calculating the parameters
necessary for correct drive and lift application operation. The order of these sequences is as follows:
●
Electrical connections
●
Setting motor parameters
●
Autotune with motor at stand-still or coupled to the load
●
Setting encoder parameters (with control mode=Flux vector CL)
●
Setting the maximum speed reference and maximum system speed
●
Setting system weights
Setting application parameters
●
●
Saving parameters
The format of the function selection page is as follows:
0
3.8 8.
Enter
Pressing the Enter key, the function to be programmed is accessed.
Press the ▼ (Down) key to move to the next function skipping the current function.
Press the ▲ (Up) key to return to the previous function.
To terminate the sequence of functions and return to the menu, press the Prg key.
The end of the start-up sequence is indicated with the page:
.
.
d o
n E
Press the Prg key to exit the sequence and return to the menu.
Step 1 - Electrical connections
Make the connections as described in paragraph 7.3.2.
Checks to be performed before powering the drive
•
Check that the supply voltage is correct and that the input terminals on the drive (L1, L2 and L3) are connected
correctly.
•
Check that the output terminals on the drive (U, V and W) are connected to the motor correctly.
•
Check that all the drive control circuit terminals are connected correctly. Check that all control inputs are open.
Powering the drive
•
After completing all the checks described above, power the drive and proceed to step 2.
84.80.
8 8.
1
1.
Enter
85.52.
8
8.80
Enter
.
8 .
Πo
t
ADL300 • Quick installation guide - Specifications and connection
.
See step 1
See step 2
See step 3
See step 4
See step 6
See step 7
See step 8
See step 9
83