4. Proceed to Preparing the server for operation.
Preparing the server for operation
Procedure
1. Install the system air baffle.
2. Install the PCI air baffle.
3. Install the access panel.
4. Do one of the following:
Server in rack mode: Install the server into the rack.
Server in tower mode: Return the server to an upright position.
5. Connect all peripheral cables to the server.
6. Connect each power cord to the server.
7. Connect each power cord to the power source.
8. Power up the server.
Enabling the Trusted Platform Module
When enabling the Trusted Platform module, observe the following guidelines:
By default, the Trusted Platform Module is enabled as TPM 2.0 when the server is powered on after installing it.
In UEFI Boot Mode, the Trusted Platform Module can be configured to operate as TPM 2.0 (default) or TPM 1.2.
In Legacy Boot Mode, the Trusted Platform Module configuration can be changed between TPM 1.2 and TPM 2.0
(default), but only TPM 1.2 operation is supported.
Enabling the Trusted Platform Module as TPM 2.0