4. Bleed the injection pump in the same way.
5. Do the bleeding with the screw (3) positioned on the
pump body.

Dry air cleaner maintenance instructions

Perform maintenance of the air cleaner in the following
way:
1. Remove the right side plate of the hood
2. Release the clamps of the air cleaner lid (marked with
arrows)
3. Remove the air cleaner lid (1)

Recovery of the mainair cleaner element

Remove the main element of the dry cleaner (2) by
pulling. If the main element is not damaged (there must
not be any dust on the inner side of the element), recover
it by blowing pressurized air from the inner side of the
element. This way you can recover the main element
3 times at the most. The element must be replaced once
a year.

Replacing the safety element of the air cleaner

- remove dry filter locking element (3) with a pull
Locking element cannot be regenerated. It must
be always replaced in these cases:
- when damaging main element
- after 5 maintenances of air filter
- at least once in two years
MAINTENANCE INSTRUCTIONS