Proper function of the heating and air-condition system

It is necessary to create surplus pressure in the cabin for
proper function of the heating or air-condition. We
therefore recommend you to close all the windows and
doors and tilting cover of the cabin.

Fast heating of the cabin area

Proceed accordingly:
1 - Turn the heating valve control (A) to the position on the
right (fully opened heating valve).
2 - Set air circulation in cabin control (D) to the position of
inner circulation.
3 - Select applicable gear of the ventilator run (position 1,
2, 3) by ventilator control (B).
4 - Set the expiration under the requested angle to avoid
direct fanning of the people in the cabin.
5 - After heating the space of the cabin, set the air
circulation in the cabin control (D) to the position of
sucking the outer air - see fig. F_02_17b position (a)

Fast cooling of the space of the cabin

Proceed accordingly:
1 - Switch the heating valve control lever (A) to the
position to the left
2 - Set the air circulation in the cabin lever (D) to the
position of outer air sucking
3 - Select an applicable gear of the ventilator run (position
1, 2, 3) by ventilator control (B)
4 - Switch the air-condition system by a switch (C)
5 - Set expiration under the requested angle so that direct
fanning of people in the cabin does not occur (the
possibility of illness due tointensive cooling of parts of
body).
Operation of heating or air-condition with tractor´s work
With engaged inner recirculation of air is the inflow of
fresh air closed and there is foul air in the space of the
cabin by operator. This state can cause the feeling of
fatigue and there can also be penetration of dust to the
cabin because of the loss of surplus pressure.
Note: Set the control (D) according to individual
requirements on temperature to the position between (a)
and (b) so that the ventilator sucks the air from the outside
of the cabin through filters, when working.
When spraying pesticides and using the
heating filter with active carbon, the recirculation
controller should be in position 'air is drawn into from
the outside' and the fan controller should be in the
position 'fan maximum work' to create overpressure
in the cabin.
ACQUAINTANCE WITH TRACTOR
39
F11N009
F_02_18a
F_02_18
F_02_19

Advertisement

Table of Contents
loading