Chapter 2 - Base Station InstallationSafety Instructions and Information
Chapter 2 - Base Station Installation
A unit with Omni antennas should be installed at the highest of point the pole. This is to ensure that
there is no interference caused by the close proximity of the antenna to other metal objects. Where
this is not possible, the unit should be installed at a distance of at least 1 meter from the pole, using a
horizontal bar.
Generally, the higher the placement of the base station, the better the link quality achievable.
However, the higher the installation the greater the interference from other sources of radiation that
the base station is exposed to. Consider best installation spot that maximizes coverage and minimizes
interference. Typically, the ideal height at which a base station should be installed is at least 3 meters
above the rooftops of the buildings within the coverage zone. Keep the maximum distance possible
from other RF radiating sources, power lines and metal objects.
The minimum vertical separation distance between two base stations is 2 meters. The minimum
horizontal separation distance between two base stations (back-to-back) with sector antennas is 2
meters. For units with Omni antennas he minimum horizontal separation distance between two base
stations (back-to-back) is 10 meters.
2.3

Safety Instructions and Information

Please ensure that you read and understand the following safety information. Ensure that you carefully
read and follow all instructions in this manual, and heed all warnings.
Do not modify the construction of this product.
There is a risk of personal injury or death if the unit is close to electric power lines.
By nature of the outdoor installation, you may be exposed to hazardous environments and high
voltage. Use extreme caution when installing the system.
Servicing may be required when the equipment has been damaged in any way. All servicing should be
referred to qualified service personnel only.
The base station must be properly grounded.
Do not open the unit - risk of electric shock.
Any change or modification not expressly described in this manual or approved by the manufacturer
could void your authority to operate this equipment.
It is recommended to install a suitable surge suppressor device to protect against overvoltage on
mains input to the equipment.
2.4

The Installation Process

IMPORTANT
Before starting the installation process note down the MAC address of the unit printed on the label.
NOTE!
Availability of this information is mandatory when IP parameters of the management interface are
obtained using DHCP.
WBSn-2400 and WBSn-2450 System Manual