Omron OMNUC W Series User Manual page 272

Ac servomotors/servo drivers
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

Operation
• If not using the soft start function, set the properties for the selected filter to 0.
Note Refer to 4-5-13 Position Command Filter Function for details.
Pn207.1
Position control setting 2 --- Speed command input switching for position control (Position)
Setting
0, 1
range
Setting Explanation
Setting
0
Function not used.
1
REF used as feed-forward input
• Set the REF function (speed command input) for position control.
• Select 1 to input the REF voltage speed feed-forward input, and add the speed equivalent to the speed
REF voltage to the speed loop command. This can shorten positioning time.
• You can change the REF voltage scale using Pn300 (speed control scale). (Default setting: 10 V/rated
rotations.)
• If using an OMRON Positioning Unit (pulse train output type), set this parameter to 0 (function not
used).
Note Refer to 4-8-4 Speed Feed-forward Function for details.
Pn207.2
Position control function 2 --- Not used.
Setting
---
range
Note Do not change the setting.
Pn207.3
Position control function 2 --- Not used.
Setting
---
range
Note Do not change the setting.
Pn208
Position command filter time constant 2 (trapezoidal acceleration and deceleration)
Setting
0 to 6400
range
• Sets the command pulse soft start. The soft start properties are linear acceleration and deceleration.
Note 1. The soft start properties also include the primary filter (the time constant set by Pn204). Select
the filter you want to use using Pn207.0 (position command filter selection).
Note 2. Refer to 4-5-13 Position Command Filter Function for details.
H Speed Control Parameters (From Pn300)
Pn300
Speed command scale (All operation modes)
Setting
150 to 3000 Unit
range
4-56
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Unit
---
Unit
---
Unit
---
Unit
x0.01 ms
0.01 V/
rated rota-
tions
Default
0
setting
Explanation
Default
0
setting
Default
0
setting
default
0
setting
Default
1000
setting
Chapter 4
Restart
Yes
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?