Appendix
H Position Control Parameters (From Pn200)
Para-
Parameter
meter
name
Digit
No.
No.
Pn200
Position
0
control
setting 1
g
1
2
3
Pn201
Encoder
Sets the number of output pulses from the Servo
divider rate
Driver.
Sets the pulse rate for the command pulses and
Pn202
Electronic
gear ratio
Servo Servomotor travel distance.
G1 (nu-
0.01 ≤ G1/G2 ≤ 100
merator)
Pn203
Electronic
gear ratio
G2 (de-
nominator)
6-14
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Explanation (See note 1.)
Name
Explanation (See note
Set-
ting
Command
0
Feed pulse
pulse
forward/reverse signal:
mode
Positive logic
1
Forward pulse/reverse
pulse: Positive logic
2
90° phase difference (A/B
phase) signal (x1):
Positive logic
3
90° phase difference (A/B
phase) signal (x2):
Positive logic
4
90° phase difference (A/B
phase) signal (x4):
Positive logic
5
Feed
pulses/Forward/reverse
signal: Negative logic
6
Forward pulse/reverse
pulse: Negative logic
7
90° phase difference (A/B
phase) signal (x1):
Negative logic
8
90° phase difference (A/B
phase) signal (x2):
Negative logic
9
90° phase difference (A/B
phase) signal (x4):
Negative logic
Deviation
0
High level signal
counter
1
Rising signal (low to high)
reset
reset
2
Low level signal
3
Falling signal (low to high)
Deviation
0
Deviation counter reset if
counter
an alarm occurs when
reset if an
Servomotor is OFF.
alarm
alarm
1
Deviation counter not
occurs
reset if an alarm occurs
when the
when Servomotor is OFF.
Servomot
Servomot
or is OFF
2
2
Deviation counter reset
Deviation counter reset
only if alarm occurs.
Pulse
0
Command filter for line
command
driver signal input (500
filter
kpps)
selection
l
ti
1
Command filter for
open-collector signal input
(200 kpps)
Default
Default
setting
tti
setting
100/200 V
400 V
2.)
1011
0000
1000
16384
4
4
1
1
Chapter 6
Unit
Setting
g
tti
range
---
---
pulse/
16 to
rotation
16384
---
1 to
65535
---
1 to
65535
Restart
power?
?
Yes
Yes
Yes
Yes

Advertisement

Table of Contents
loading