Configure:base:poweroff 0|1; Configure:vip:analyze:auto On|Off|1|0; Configure:vip:analyze:auto; Fetch:gpsdata:reset - Anritsu Site Master S331L Scpi Programming Manual

Handheld cable and antenna analyzer
Hide thumbs Also See for Site Master S331L:
Table of Contents

Advertisement

Chapter 3 — All Mode Commands

:CONFigure:BASe:POWeroff 0|1

Cmd Description: Command cycles the power to the instrument (0) or turns it completely
Param Range: 0 for power cycling, 1 for turning instrument off
Example: To cycle the system power:

:CONFigure:VIP:ANALyze:AUTO ON|OFF|1|0

:CONFigure:VIP:ANALyze:AUTO?

Cmd Description: Command sets auto analyze state.
Query Description: Query returns auto analyze state. Query returns 1 if auto analyze is on.
Param Range: ON|OFF|1|0
Default Value: OFF|0
Example: To set auto analyze state to on:

:FETCh:GPSData:RESet

Cmd Description: Reset the current and last GPS data.
Example: To reset GPS data:

:FETCh:GPSData? {CURRent|LAST}

Query Description: Query returns the current or the last GPS data. If no parameter is
Param Description: Optional Param: GPS data collection type, default is CURRent.
Param Range: CURRent|LAST
Example: Query the current GPS data:
S331L PM
off (1). Cycling the power does not save the current setup (instrument
will restart with last saved setup) whereas turning the instrument off
will store the current setup.
:CONF:BAS:POW 0
Otherwise, it returns 0.
:CONF:VIP:ANAL:AUTO ON
:FETC:GPSD:RES
entered, it defaults to return current GPS data. Latitude and longitude
units are in radians. Altitude units are in meters. Return format: No
H/W Found|No Fix|Good Fix
(3D),<time-stamp>,<latitude>,<longitude>,<altitude>|Good Fix
(2D),<time-stamp>,<latitude>,<longitude>
:FETC:GPSD? CURRent
PN: 10580-00322 Rev. F
3-3