Chapter 4 — Cable & Antenna Analyzer Mode Commands
:CALCulate:MARKer#:Y?
Query Description: Query returns the amplitude value for the specified marker.
Example: To query marker 3 amplitude value:
Notes: Replace '#' with the required marker number. Check User Guide for the
:CALCulate:MARKer#[:STATe] OFF|ON|0|1
:CALCulate:MARKer#[:STATe]?
Cmd Description: Command sets the state of the specified marker.
Query Description: Query returns the state of the specified marker. Query returns 1 if the
Param Range: OFF|ON|0|1
Default Value: OFF|0
Example: To set marker 1 state ON:
Notes: Replace '#' with the required marker number. Check User Guide for the
:CALCulate:MARKer:ACTive?
Query Description: Query returns active marker number. Returns NONE if no markers are
Example: To get active marker
:CALCulate:MARKer:DISPlay MKRTable|MKRonly|AOFF
:CALCulate:MARKer:DISPlay?
Cmd Description: Command sets the marker display mode.
Query Description: Query returns the marker display mode. Query returns MKRT if the
Param Range: MKRTable|MKRonly|AOFF
Default Value: MKRTable
Example: To set marker display to marker only:
S331L PM
:CALC:MARK3:Y?
number of supported markers in each mode.
specified marker is on, or returns 0 if the specified marker is off.
:CALC:MARK1 ON
number of supported markers in each mode.
active.
:CALC:MARK:ACT?
markers and marker table are displayed, returns MKR if only the
markers are displayed, or returns AOFF if markers and marker table
are not displayed.
:CALC:MARK:DISP MKR
PN: 10580-00322 Rev. F
4-13