:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP <amplitude>{dB}

:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP?

Cmd Description: Command sets the display top value.
Query Description: Query returns the display top value.
Param Type: Float
Default Value: Return Loss = 0dB; DTF Return Loss = 0dB; Cable Loss = 0dB; VSWR =
Default Units: dB
Example: To set trace top value in Return Loss to 10 dB:

:FORMat[:READings][:DATA] ASCii|INTeger,32|REAL,32

:FORMat[:READings][:DATA]?

Cmd Description: Command sets the data format type. ASCii and REAL returns data in
Query Description: Query returns the data format type as ASC or INT, 32 or REAL, 32.
Param Range: ASCii|INTeger,32|REAL,32
Example: To set data format type to integer:
Notes: INTeger,32 values are signed 32-bit integers in little-endian byte order.

:FORMat[:READings][:DATA]:MULTiplier 1|1M

:FORMat[:READings][:DATA]:MULTiplier?

Cmd Description: Command sets the data format multiplier factor.
Query Description: Query returns the data format multiplier factor. If '1M' is passed as
Param Range: 1|1M
Default Value: 1M
Example: To set data format multiplier to 1:
4-20
Chapter 4 — Cable & Antenna Analyzer Mode Commands
3; DTF VSWR = 3; Transmission = 10dB; Phase = 225
:DISP:WIND:TRAC:Y:TOP 10
current unit. INTeger returns data with mdBm unit. This command
applies to :TRACe[:DATA]? and :CALCulate:DATA?.
:FORM INT,32
This format returns the data in 4-byte blocks. REAL,32 values are
32-bit floating point numbers conforming to the IEEE 754 standard in
little-endian byte order. This format returns the data in 4-byte binary
format. The units are the current instrument units. Both INTeger and
REAL formats return a definite block length. Each transfer begins with
an ASCII header, such as #42204 for INTeger,32 and REAL,32. The
first digit represents the number of following digits in the header.
argument, then query results for :TRACe[:DATA]? and
:CALCulate:DATA? will specify readings multiplied by 10^6. If '1' is
passed, then query results for :TRACe[:DATA]? and :CALCulate:DATA?
will specify read.
:FORM:MULT 1
PN: 10580-00322 Rev. F