Anritsu Site Master S331D Maintenance Manual
Anritsu Site Master S331D Maintenance Manual

Anritsu Site Master S331D Maintenance Manual

Cable and antenna analyzer
Hide thumbs Also See for Site Master S331D:

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Site Master S331D and is the answer not in the manual?

Questions and answers

Summary of Contents for Anritsu Site Master S331D

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 Site Master Model S331D Cable and Antenna Analyzer MAINTENANCE MANUAL 490 JARVIS DRIVE · MORGAN HILL, CA 95037-2809 P/N: 10580-00101 REVISION H PRINTED: OCTOBER 2012 COPYRIGHT ã 2004-2012 ANRITSU CO.
  • Page 4: Table Of Contents

    Table of Contents 1. Introduction ......... . . 1 2.
  • Page 6: Introduction

    The following test can be used to verify the CW frequency accuracy of the Site Master. Measurement cali- bration of the Site Master is not required for this test. a. Equipment Required: · Spectrum Analyzer Anritsu Model MS2665C or equivalent · 10 MHz Reference Standard b. Procedure: 1.
  • Page 7: Vna Return Loss Verification

    Equipment Required: · 20 dB offset, Anritsu SC7423 · 6 dB offset, Anritsu SC7424 · Open/Short, Anritsu 22N50 · 50 Ohm Termination, Anritsu 28N50-2 or SM/PL b. Procedure: 1. Press and hold the key, then press the key to turn on the Site Master.
  • Page 8: Power Monitor Verification (Option 5)

    The following test can be used to verify the accuracy of the power monitor function. a. Equipment Required: · Anritsu MG3692A Synthesized Signal Source, with options 2A, 4 and 15A · Anritsu ML2438A Dual Channel Power Meter or equivalent · Anritsu MA2442D High Accuracy Power Sensor or equivalent ·...
  • Page 9 7. Connect the external power supply (Anritsu part number 40-187-R) to the Site Master. 8. On the Site Master, press and hold the key, then press the key to turn on ESCAPE/CLEAR ON/OFF the Site Master. (This sets the instrument to the factory preset state.) 9.
  • Page 10: Power Meter Verification (Option 29)

    The following test can be used to verify the accuracy of the power measurements. a. Equipment Required: · Anritsu MG3692A Synthesized Signal Source, with options 2A, 4 and 15A · Anritsu ML2438A Dual Channel Power Meter or equivalent · Anritsu MA2442A High Accuracy Power Sensor or equivalent ·...
  • Page 11 8. Disconnect Sensor A from the MG3692A output. 9. Connect the power splitter to the MG3692A output and the Sensor B to one of the power splitter outputs. Install the 10 dB Fixed Attenuator to the other power splitter output and then connect Sensor A to the end of the Attenuator.
  • Page 12 AMPLITUDE MEAS/DISP S331D Figure 3. Power Meter Verification Setup 18. Connect the external power supply (Anritsu part number 40-187-R) to the Site Master. 19. On the Site Master, press and hold the key, then press the key to turn on...
  • Page 13: T1/E1 Verification (Option 50)

    This procedure verify that the T1/E1 Tester of the Site Master is functioning properly. a. Equipment Required: · Tektronix TDS3032B Oscilloscope with option TDS 3TMT · Tektronix AFTDS Differential Signal Adapter · Anritsu Bantam-Plug-to-Bantam-Plug Extender Cable (P/N 806-16) T1/E1 Self Test 1. Press and hold the key, then press the key to turn on the Site Master.
  • Page 14 E1 Mask Test 1. Set the Adapter switch to 120 ohms and connect it to the scope. 2. Connect the Extender cable to the Transmit port of the Site Master. 3. Press and hold the key, then press the key to turn on the Site Master. ESCAPE/CLEAR ON/OFF (This sets the instrument to the factory preset state.)
  • Page 15 9. Press the soft key, then press the soft key. Internal Back 10. Press the soft key and select , then press the soft key twice. Transmit Level 0 dB Back 11. Press the soft key, then use the Up/Down arrow key to highlight and press the Pattern 1 IN 8...
  • Page 16 3. Press the key and the soft key, and use the soft key to select MEAS/DISP Terminate/Bridged Termi- at the bottom of the display. nate 4. Press the soft key, then press the soft key. Back BERT 5. Press the key and select the soft key.
  • Page 17: Instacal Module Verification

    8. InstaCal Module Verification This test verifies the performance of the Anritsu Site Master InstaCal Calibration Module. The InstaCal Module, part number ICN50, is an optional accessory for the S331D. a. Equipment Required: · InstaCal Module, part number ICN50 · 20 dB offset, Anritsu SC5270 ·...
  • Page 18: Battery Pack Removal And Replacement

    9. Battery Pack Removal and Replacement This procedure provides instructions for removing and replacing the Site Master battery pack. NOTE: Many of the procedures in this section are generic, and apply to many similar instruments. Photos and illustrations used are representative and may show instruments other than the Site Master. 1.
  • Page 19 3. Lift the door and remove, as illustrated in Figure 6. Figure 6. Removing the Battery Access Door 4. Grasp the battery lanyard and pull the battery straight up and out of the unit, as illustrated in Fig- ure 7. Figure 7.
  • Page 20: Battery Information

    · Use only Anritsu approved battery packs. · Recharge the battery only in the Site Master or in an Anritsu approved charger. · With a new NiMH battery, full performance is achieved after three to five complete charge and dis- charge cycles.
  • Page 21 10.1. Battery Testing Procedure 1. With the Site Master off and the battery installed, connect the Universal AC Adapter to the connector. The LED and the LED will light. 12.5-15VDC (1350 mA) External Power Battery Charging NOTES: If the Battery Charging LED does not light, the battery may be too low to immediately start full charging.
  • Page 22: Front Panel Assembly Removal And Replacement

    11. Front Panel Assembly Removal and Replacement This procedure provides instructions for removing and replacing the Site Master front panel assembly. With the front panel assembly removed, the LCD display, keypad PCB, keypad membrane, and main PCB assemblies can be removed and replaced. NOTE: Many of the procedures in this section are generic, and apply to many similar instruments.
  • Page 23 8. Carefully disconnect the LCD display backlight cable from J1 on the main PCB. Figure 11. Site Master Front Panel Cable Connections 9. Remove the front panel assembly. 10. Reverse the above steps to replace the front panel assembly. NOTE: The corner bumpers only mount one way. That is, the raised area inside one end of the bumper (Figure 10) is made to conform to the contour of the front cover only.
  • Page 24: Lcd Assembly Replacement

    12. LCD Assembly Replacement This procedure provides instructions for removing and replacing the Liquid Crystal Display (LCD) once the front panel assembly has been separated from the Site Master. 1. Remove the front panel assembly as directed in section 11. 2.
  • Page 25: Key Pad Pcb Replacement

    13. Key Pad PCB Replacement This procedure provides instructions for removing and replacing the key pad PCB. 1. Remove the front panel assembly as directed in section 11. 2. Place the front panel assembly face down on a protected work surface. 3.
  • Page 26: Key Pad Membrane Replacement

    14. Key Pad Membrane Replacement This procedure provides instructions for replacing the key pad membrane. 1. Remove the front panel assembly as directed in section 11. 2. Remove the key pad PCB as directed in section 13. 3. Remove the keypad membrane by gently pulling the membrane up and out of the holes in the front panel.
  • Page 27: Main Pcb Assembly Replacement

    15. Main PCB Assembly Replacement This procedure provides instructions for replacing the main PCB assembly with the connector panel at- tached. 1. Remove the front panel assembly as directed in section 11. 2. Disconnect the battery connector from J7 on the main PCB. 3.
  • Page 28: Option 5 Power Monitor Pcb Assembly Replacement

    16. Option 5 Power Monitor PCB Assembly Replacement This procedure provides instructions for replacing the Power Monitor PCB Assembly. 1. Remove the front panel assembly as directed in on page 17, Front Panel Assembly Removal and Replacement. 2. Remove the entire Main PCB assembly from the bottom case as directed on page 22. 3.
  • Page 29: Option 50 T1/E1 Tester Pcb Assembly Replacement

    17. Option 50 T1/E1 Tester PCB Assembly Replacement This procedure provides instructions for replacing the T1/E1 Tester PCB assembly. 1. Remove the front panel assembly as directed in on page 17, Front Panel Assembly Removal and Replacement. 2. Remove the entire Main PCB assembly from the bottom case as directed on page 22. 3.
  • Page 30: Accessories And Replaceable Parts

    18. Accessories and Replaceable Parts Accessories and replaceable parts for the Site Master S331D are listed below. Accessories Part Number Description 10580-00079 User’s Guide, Site Master S33xD 10580-00100 Programming Manual, Site Master S33xD (disk only) 2300-347 Handheld Software Tools 40-187-R...
  • Page 31 67199-3 Keypad PCB Assembly 46649-4 Membrane Keypad, Main, with Contrast symbol 46649-6 Membrane Keypad, Main, without Contrast symbol Hardware Part Number Description 900-861 Pan Head Screw, 4-20, 0.365 900-791 Screw, 2-56, 0.375 900-720 Screw, 4-40, 0.187 900-326 Kep Nut, 4-40, 0.187 790-18 M-F Standoff, 4-40, 0.375, Hex 785-927...
  • Page 32: Customer Service

    19. Customer Service To locate the nearest Anritsu Customer Service Center, please refer to the Anritsu web page: http://www.anritsu.com/Contact.asp Site Master MM...

Table of Contents