[:SENSe]:RFON[:STATe] ON|OFF|1|0
[:SENSe]:RFON[:STATe]?
Cmd Description: Command sets the RF power output state when the sweep is in Hold
Query Description: Query returns the RF power output state when the sweep is in Hold
Param Range: ON|OFF|1|0
Default Value: ON|1
Example: To set RF power output state off:
[:SENSe]:ROSCillator[:SOURce]?
Query Description: Query returns reference oscillator setting. Query returns INT for
Example: To query reference oscillator:
[:SENSe]:SWEep:IFBW <frequency>{ Hz|kHz|MHz|GHz}
[:SENSe]:SWEep:IFBW?
Cmd Description: Command sets the IF bandwidth. The permissible values are 10Hz,
Query Description: Query returns the IF bandwidth.
Param Type: Float
Param Description: Bandwidth frequency
Default Units: Hz
Example: To set IFBW to 1000Hz:
[:SENSe]:SWEep:RESolution 130|259|517|1033|2065
[:SENSe]:SWEep:RESolution?
Cmd Description: Command sets the data points.
Query Description: Query returns the data points as a number.
Param Range: 130|259|517|1033|2065
Default Value: 259
Example: To set data points to 1033:
4-28
Chapter 4 — Cable & Antenna Analyzer Mode Commands
mode.
mode.
:RFON OFF
internal or EXT for external.
:ROSC?
100Hz, 1kHz, 2kHz, and 100kHz.
:SWE:IFBW 1 kHz
:SWE:RES 1033