EDITION 04/2012
OPERATING MANUAL
5.4.12

SETTING THE HIGH VOLTAGE

80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
8
7
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
8
Above the „High voltage" button (7) is the „High voltage" bar graph display 21). When the
control unit is in the ready position, this display shows the set point as a dot.
PART NO. DOC2321362
Works procedure:
1. Press the „High voltage" button (7) to
adjust the high voltage. The LED (8)
POWER
POWER
indicates that high voltage is selected.
0
1
AquaCoat
B_03375
27
2. The high voltage can now be adjusted
using the universal rotary controller (2)
between 5 to 70 kV with a resolution
of 1 kV. The value is shown in the LED
POWER
POWER
0
1
display (27).
AquaCoat
B_03376
7
AquaCoat GM 5000EACW
53