Setting The High-Voltage - WAGNER Prima Sprint Airfluid Translation Of The Original Operating Manual

Manual powder system
Table of Contents

Advertisement

VERSION 07/2009
OPERATING MANUAL
6.5.4

SETTING THE HIGH-VOLTAGE

28
27
P_01121
1
Above the "high-voltage" button 27 is the "high-voltage" bar graph display 1. When the
control unit is in the ready position, this display shows the set point as a dot and when
high-voltage is switched on it shows the actual value as a bar.
As mentioned above, the high-voltage can be adjusted between 10 kV - 100 kV. If the value
is set to 10 kV and is then reduced further, the word "off" appears in the display to indicate
that high-voltage is switched off. As a result, high-voltage generation is not switched on
when powder feeding is switched on.
ORDER NUMBER DOC 2305835
EP G
SPR INT
EP G
SPR INT
Prima
Procedure:
1. Press the "high-voltage" button 27 to
adjust the high-voltage. The yellow
LED 28 indicates that high-voltage is
selected.
19
2. The
high-voltage
adjusted using the Universal rotary
controller 24 between 10 kV - 100 kV
with a resolution of 1 kV. The value is
shown in the LED display 19.
24
Sprint.
can
now
be
48

Advertisement

Table of Contents