7.4.8 SETTING THE HIGH VOLTAGE

80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
8
7
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
7
21
Above the "High-voltage" button (7) is the "High-voltage" bar graph display (21).
If the control unit is in the ready position, this light strip shows the set value as a dot.
ORDER NUMBER DOC 2369735
Procedure
1. Press the "High-voltage" button (7)
to adjust the high voltage.
The LED (8) indicates that high voltage
is selected.
POWER
POWER
0
1
AquaCoat
B_03375
27
2. The high voltage can now be
adjusted using the universal rotary
controller (2) between 5 to 80 kV
with a resolution of 1 kV.
The corresponding value is
indicated in the LED display (27).