6.5

ASSEMBLY AND INSTALLATION

WARNING
Inclined ground!
Risk of accident if device falls over.
Place device on level ground and secure it.
National regulations
Ensure that the national explosion prevention rules and regulations are observed
when setting up the device.
This pump can be used as part of a spraying system for
Airless or AirCoat applications. Individual supplement
components for this pump can be found in the Wagner
accessories catalogue. The nozzles must be selected
according to the gun instructions. The pump (1) is already
pre-mounted on a frame at the factory.
Procedure:
1. Mount the return valve (4) for pressure relief or
product circulation.
Notice: To ensure enough space for assembly, the
return valve must be assembled in open position
(image shows closed position).
2. Connect high-pressure hose (2) and spray gun (3)
according to gun operating manual.
To prevent potential transportation issues, the separating
fluid chamber of the pump is not filled at the factory.
Remove the two caps (5), fill up the chamber with separating
agent, as shown in the figure (6), and then replace the caps.
ORDER NUMBER 2351778
EvoMotion 40-15 S-HE
EvoMotion 20-30 S-HE
3
AirCoat system
2
4
5
LEVEL
5
C_HE_00006
1
5
C_HE_00013
6
5
5
26