Wiring
22
4.3

Terminal assignment

Terminal compartment A
90 ... 253 VAC
18 ... 36 VDC
L1
N
+
L+
L-
14
(3)
1
2
Terminal(s)
Meaning
0
Grounding of the cable screen
1, 2
Power supply
Compartment B:
Signal output, depending on the communication version:
3, 4
• 4-20mA with HART
Compartment A:
• PROFIBUS PA
1
1
(3)
,(4)
• Foundation Fieldbus
(The signal output is situated in the terminal compartment A or B depending on the instrument
version, see below.)
!
Note!
For the versions of the Gammapilot M with fieldbus plug connectors (M12 or 7/8"), the signal
output is wired in compartment B on delivery and connected to the fieldbus plug connector (see
below, section "Fieldbus plug connectors"). In this case, the housing needs not to be opened for
connecting the signal line.
5, 6
Pulse input (for cascading mode; is used for master and slave)
7, 8
Pulse output (for cascading mode; is used for slave and end slave)
9, 10, 11, 12
PT100 input (4-wire)
13
Plug for display and operating module VU331 (normally in FHX40);
is wired on delivery and connected to the FHX40 plug
14
Protective earth
15
Protective earth or grounding of the cable screen
1)
rated cross section max. 2,5 mm
Terminal compartment B
-
15
(4)
L00-FMG60xxx-04-00-00-xx-002
1
2
Gammapilot M FMG 60 - PROFIBUS PA
OFF
ON
SIM WP
PT100
13
9 10 11 12
IN CASCADE OUT
+ -
+ -
-
3 4
5 6
7 8
0
L00-FMG60xxx-04-00-00-xx-001
+