Gammapilot M FMG 60 - PROFIBUS PA
Ambient temperature
Climate class
Degree of protection
Vibration resistance
Shock resistance
Electromagnetic compatibility
Process temperature
Process pressure
Dimensions, weight
Materials
10.1.6
Ambient conditions
Instrument version
without water cooling
PVT Scintillator
NaI crystal
1)
If the ambient temperature permanently exceeds +40 °C, water cooling is recommended.
2)
max. 75 °C at the compartment housing
3)
If the ambient temperature permanently exceeds +50 °C, water cooling is recommended.
In explosion hazardous areas observe the instructions of the appropriate XA/ZD.
Avoid exposure to direct sunlight; if necessary use a protective cover.
DIN EN 60068-2-38 examination Z/AD
IP 65/67; NEMA 4/6; TYPE 4/6
DIN EN 60068-2-64; Examination Fh; 10 ... 2000 Hz, 1(m/s
DIN EN 60068-2-27; Examination Ea; 30 g, 18 ms, 3 shocks/direction/axis
• Interference emission to EN 61326, Equipment class B
• Interference immunity to EN 61326, Appendix A (Industrial) and NAMUR recommendation
NE 21
10.1.7
Process conditions
no limitations;
for high process temperatures sufficient isolation between process vessel and detector must be
ensured (see table of ambient temperatures, page 93).
no limitations;
the influence of pressure must be taken into account when calculating the required activity and
calibrating.
10.1.8
Mechanical construction
s. chapter "mounting conditions"
• Housing: SS316L
• Sealing materials:
– housing: FKM
– cable glands: EPDM; TPE-V
Ambient temperature
with water cooling
1
-40 °C ... +50 °C
0 °C ... +120 °C
3
-40 °C ... +60 °C
0 °C ... +120 °C
Technical Data
Storage temperature
2
-40 °C ... +50 °C
2
-40 °C ... +60 °C
2
2
)
/Hz
93