Otto Bock 6A20-10 Instructions For Use Manual page 9

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
die durch Nichtbeachtung dieses Dokuments, insbesondere durch
unsachgemäße Verwendung oder unerlaubte Veränderung des Pro­
dukts verursacht werden, haftet der Hersteller nicht.
8.2 CE-Konformität
Das Produkt erfüllt die Anforderungen der Verordnung (EU) 2017/745
über Medizinprodukte. Die CE-Konformitätserklärung kann auf der
Website des Herstellers heruntergeladen werden.
9 Technische Daten
Kennzeichen
Gewicht [g]
Systemhöhe [mm]
Einbauhöhe [mm]
Material (Eingussanker)
Material (ShuttleLock)
Max. Körpergewicht [kg]
1 Product description
INFORMATION
Date of last update: 2022-03-03
► Please read this document carefully before using the product
and observe the safety notices.
► Instruct the user in the safe use of the product.
► Please contact the manufacturer if you have questions about the
product or in case of problems.
► Report each serious incident related to the product to the manu­
facturer and to the relevant authority in your country. This is par­
ticularly important when there is a decline in the health state.
► Please keep this document for your records.
6A20=10
6A20=20
425
485
25
79
43
61
Stahl
Aluminium
125
English
1.1 Construction and Function
The 6A20=10, 6A20=20 shuttle lock serves to secure a suitable liner
in the prosthetic socket. A lamination anchor is laminated into a the
prosthetic socket. Then the shuttle lock is screwed into the lamination
anchor.
1.2 Combination possibilities
This prosthetic component is compatible with Ottobock's system of
modular connectors. Functionality with components of other manufac­
turers that have compatible modular connectors has not been tested.
2 Intended use
2.1 Indications for use
The product is intended exclusively for lower limb exoprosthetic fit­
tings.
2.2 Area of application
The maximum approved body weight is specified in the technical
data (see page 14).
2.3 Environmental conditions
Allowable environmental conditions
Temperature range for use: -10 °C to +60°C
Allowable relative humidity 0 % to 90 %, non-condensing
Unallowable environmental conditions
Mechanical vibrations or impacts
Perspiration, urine, fresh water, salt water, acids
Dust, sand, highly hygroscopic particles (e.g. talcum)
2.4 Lifetime
Depending on the patient's level of activity, the service life of the
product is 3 to 5 years.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

6a20-20

Table of Contents