Chapter 2
Preparing for Installation
GRP RJ-45 Ethernet Connections
OL-11495-01
The RJ-45 Ethernet connection does not require an external transceiver.
Figure 2-15
shows the pin orientation of the RJ-45 Ethernet port and the modular
cable plug it accepts.
Figure 2-15 GRP RJ-45 Ethernet Receptacle and Modular Plug
8 7 6 5 4 3 2 1
RJ-45 connector
Table 2-4
lists the RJ-45 pin signals used on the connector.
Table 2-4
GRP RJ-45 Ethernet Receptacle Pinout
Ethernet Port
Pin
Signal
1
TxD+
2
TxD–
3
RxD+
4
Termination network
5
Termination network
6
RxD–
7
Termination network
8
Termination network
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
GRP Port Connection Guidelines
Description
Transmit data +
Transmit data –
Receive data +
No connection
No connection
Receive data –
No connection
No connection
2-31