Encryption Type: Select an encryption type for data transmitted over the wireless
interface. When encryption is enabled, no Ethernet packets can be transferred over-the-
air unless encryption is enabled on the remote-end AN-80i, and the correct Encryption
Key is entered on both AN-80i units.
None: Encryption is disabled.
Redline 64-bit: Redline proprietary encryption scheme, compatible with AN-50e.
AES 128-bit: Advanced Encryption Standard using 128-bit encryption.
AES 192-bit: Advanced Encryption Standard using 192-bit encryption.
AES 256-bit: Advanced Encryption Standard using 256-bit encryption.
Encryption Key: The key is used to encrypt data in a way that can be decoded by the
remote-end AN-80i. Enter the MAC address of the communicating AN-80i.
Link Name: Enter the name to be used for both the local and remote-end system. A
PTP wireless link can be established only between a pair of AN-80i systems where the
Link Name field setting is identical. This feature ensures that on power-up, reboot, or
auto scan (following deregistration or DFS event), wireless links will only register with
designated remote-end units.
Important: To establish a PTP wireless link between an AN-50e and AN-80i system,
the AN-80i Link Name field must be blank (delete all characters).
Link Length Measurement Mode: Select the mode for setting/measuring the distance
between this and the remote-end AN-80i.
Auto: Distance is calculated automatically by the AN-80i.
Manual: Enter the link distance manually in the
Link Length: Enter the actual length of the path that the radio wave travels between the
two AN-80i units. The link length is used to calculate the transmission-to-response
interval and reject reflections of the transmitted signal. This setting is valid only when the
Link Length Mode is set to Manual.
Link Length Measurements Unit: Select the units for the
Mile:
Link
Km:
Link
Antenna Alignment Buzzer Enable: Check this box
audible tone generator in the transceiver. The rate of the tone is proportional to the
receive signal strength (faster = stronger signal).
Radio Enable: Check this box
( ), it will not be possible to establish a wireless link.

Controls

Save: Click to save settings currently displayed in the configuration screen. Changes to
some parameters cause a system reset when the Save button is selected.
Test: Click this button to load the current settings displayed in the configuration screen.
The AN-80i will operate with these settings for a period of five minutes. During the 'test'
period, you may click the Save button at any time to save this configuration permanently
(also terminating the five minute timer). If the Save button is not selected, the previous
saved settings are reloaded.
System Reboot: Click this button to immediately reboot the AN-80i. All statistics
counters are reset.
70-00072-01-06a
length distance is displayed in miles.
length distance is displayed in kilometers.
Proprietary Redline Communications © 2008
AN-80i
Length field.
Link
to enable the radio transmitter. If this box is unchecked
Manual
Length field.
Link
to enable the antenna alignment
Page 33 of 96
User
June 1, 2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Redconnex an-80i

Table of Contents