Testing And Saving System Parameters; Cli Interface; Web Interface; Figure 37: Diag: - Saving Parameters In Nvram - Redline Communications RedCONNEX AN80IB User Manual

Table of Contents

Advertisement

6.3

Testing and Saving System Parameters

The AN-80i is a highly configurable communications device. All user settings are saved
in non-volatile RAM. The system configuration and snmp settings are saved separately.
6.3.1

CLI Interface

Use the 'test' command to have the AN-80i load the edited settings. The AN-80i will
operate with these settings for a period of five minutes. During the test period, you may
click the Save button at any time to save this configuration permanently. Otherwise, after
five minutes, the AN-80i will reboot and load the previously saved settings.
Note: Factory defaults can only be restored using the CLI commands.
6.3.2

Web Interface

The Test button is located on the System Configuration page. Click this button to have
the AN-80i load the current settings displayed in the configuration screen. The AN-80i
will operate with these settings for a period of five minutes. During the test period you
may click the Save button at any time to save this configuration permanently (also
terminating the five minute timer). After five minutes, if the Save function button has not
been applied, the AN-80i will reboot and load the previously saved settings.
Attempt to login to the AN-80i using a Web browser. Microsoft Internet Explorer is
recommended. If the AN-80i does not respond by displaying the login dialog box, check
that the correct IP address is being used. The value 192.168.25.2 is the factory default
value and may have been changed during installation.
Test is to verify the IP address is reachable from the computer. Use the ping command
to test the
Connection
>ping 192.168.25.2
If the ping test is successful, the host computer was able to send and receive packets
to/from the AN-80i. The problem may be with the Internet browser or related settings on
the host computer. Reboot the host computer to try to resolve the problem.
70-00072-01-06a

Figure 37: Diag: - Saving Parameters in NVRAM

between the AN-80i and host computer.
Proprietary Redline Communications © 2008
AN-80i