The PTP status code is displayed in a series of decimal characters representing the
status of six different alarm conditions. The value '1' indicates the associated condition is
active. All unused bits are set to zero.
To determine the status, the decimal number must be converted to binary notation. It is
recommended to use a scientific calculator that supports binary notation (i.e., Windows
on-screen calculator). Set the mode for decimal and enter the status code. Change the
mode to binary and match active bits (1) to the following table.
For example, if 'RF High Temp. Warning' (2) and ' PHY lock error' (1 0000) were active,
the status code value would be 34 (binary 100010) (leading zeros are not displayed).
Error Type
Tx Power
RF High
Temp.
Warning
RF PLL Lock
Error
PHY lock
error
80 MHz PLL
lock error
Firmware
Configuration
Error
70-00072-01-06a

Table 36: Diag. - PTP Status Codes

Error #
Error #
Decimal*
(binary)
1
2
16
32
10 0000
64
100 0000
128
1000 0000
*Displayed decimal value if this is the only active error condition.
Proprietary Redline Communications © 2008
AN-80i
Description
1
Power output is less than 10 dBm. This message
may appear before the RF link is established.
10
The transceiver internal temperature rose above
185F / 85C. The transceiver will shut down for 30
seconds to allow cooling.
1 0000
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
Error detected in the AN-80i configuration file.
Manual
Page 83 of 96