Pmp Screens; Configuration Screen; Figure 23: Pmp - Wireless Settings - Redline Communications RedCONNEX AN80IB User Manual

Table of Contents

Advertisement

4.4

PMP Screens

This section describes the configuration screens used to setup a PMP deployment.
4.4.1

Configuration Screen

Click
Configure System
system identification, Ethernet, and the wireless interface (partial screen shown below).
The highlighted wireless settings are specific to PMP deployments.
System Mode: The system designated as sector controller establishes and manages
the bi-directional data link with a remote end AN-80i. Only one system in a wireless link
must be set for Sector Controller mode.
PTP Sector Controller: AN-80i begins transmitting automatically, sends poll
messages to locate remote AN-80i subscribers, and negotiates operating settings for
the link.
PTP Subscriber: AN-80i waits passively, monitoring the selected channel(s) until
polled by the PTP Sector Controller.
Registration Period: The polling period for detecting new subscribers. Period is based
on the number of wireless frames transmitted. Permitted values are 1 to 400. The
recommended default registration period is 4.
Max. Distance [km]: Enter the distance to the subscriber located farthest away from the
sector controller (outer boundary of sector). This parameter is used to optimize
communications with the subscribers.
70-00072-01-06a
in the menu to view and adjust configuration settings for general

Figure 23: PMP - Wireless Settings

Proprietary Redline Communications © 2008
AN-80i
Page 46 of 96
User
Manual
June 1, 2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Redconnex an-80i

Table of Contents