PMP Status Codes

The PMP status code is displayed in a series of hexadecimal characters representing
the status of different alarm conditions. The value '1' indicates the associated condition
is active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation.
It is recommended to use a scientific calculator that supports binary notation (i.e.,
Windows on-screen calculator). Set the mode for Hex and enter the status code.
Change the mode to binary and match active bits (1) to the PMP Status Codes table.
For example, if 'Radio Over Temperature' bit 1 and 'PLL Error' bit 4 were active, the
status code value would be Hex '12' (binary 1 0010).
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9
Bit
1
4, 5, 6
8
16
17, 18, 19, 20,
21, 22, 23, 24,
25, 26, 27, 28
70-00072-01-06a

Table 37: Diag. - PMP Status Code Bits

Table 38: Diag. - PMP Status Codes

Description
Radio over-temperature
PLL Errors
Firmware Error
No Ethernet packets received by the wireless MAC
MAC Internal Errors
Proprietary Redline Communications © 2008
AN-80i
Page 84 of 96
User
Manual
8
7
6
5
4
3
2
1
June 1, 2008
0