PTP
PMP
70-00072-01-06a
Parameter/Description
conpri: Connection priority.
<id>
- [id number]
<pri>
- <VLAN priority>
convid: Connection VLAN ID.
<id>
- [id number]
<vid>
- <VLAN ID>
conviden: Connection VLAN enable.
<id>
- [id number]
<mode>
dfsaction: Select the mode of operation for DFS. The system set to master-
mode monitors for interference from radar devices and other equipment using
the same channel frequency. When interference is detected, the system
automatically takes the action selected using the drop-down menu:
<action>
- [none=0 | txoff=1 | chgfreq=2]
None: The DFS function is disabled.
Tx Off: Transmission is immediately disabled when radar signals are
detected. This action is recorded in the message log and an SNMP trap
message is sent (if SNMP enabled).
Chg Freq: Relocate transmission to an alternative frequency immediately
when radar signals are detected. This action is recorded in the message
log and a trap message is sent (if SNMP enabled).
dlqos: Downlink QoS.
<id>
- [id number]
<qos>
- <QoS>
dlrate: Downlink rate.
<id>
- [id number]
<rate>
- <rate>
dst: Enter the actual length of the path that the wave travels in order to
establish the link. Units are defined by dstmu setting.
This value is used to calculate the transmission-to-response interval and
disregard reflections of the transmitted signal. Used only if dstmod is set to
'manual'.
dstmode: Select the mode for determining the distance of the wireless link.
auto: Distance is calculated automatically by the AN-80i.
manual: Operator enters link distance.
dstmu: Select the measurement unit for the link length (dstmode).
mile - dstmode units are miles
km - dstmode units are kilometers
efw: Enable or disable the Ethernet Follows Wireless function.
off - Disable
on - Enable
When Ethernet Follows Wireless is enabled the Ethernet port status is
controlled to reflect the status of the wireless interface. When the AN-80i
detects that the wireless interface has failed (or is manually disabled), the local
Ethernet port is immediately disabled. The Ethernet port is enabled when the
AN-80i registers on the wireless link.
Proprietary Redline Communications © 2008
AN-80i
Table 27: CLI - set
- <on/off>
Page 69 of 96