also be aware that the surrounding rugged system components and chassis can get very
hot!
Warning!
Care must be taken when applying the procedures below to ensure that
neither the CP6003-RC nor other system boards are physically damaged
by the application of these procedures.
2. Ensure that the CP6003-RC is ready for hot-swapping.
Note ...
What transpires at this time is a function of the application. In any event,
some means of indication or notice must be made available that the
CP6003-RC requires and is ready to be hot-swapped.
Do not proceed with the remaining procedures until it is verified that a
hot-swap may be performed.
3. Unfasten both extractor handle retaining screws.
4. Ensure that both the top and bottom wedge locks are fully relaxed.
To relax the wedge lock, turn the wedge lock's screw counter-clockwise using a 2.5 mm
hex key until the screw is against the stop.
Warning!
Due care should be exercised when handling the board due to the fact that
the heat spreader can get very hot - danger of burns. In addition, the sur-
rounding rugged system components and chassis may be very hot.
If required, use protective gloves to handle the CP6003-RC when remov-
ing it.
5. Disengage the board from the backplane using the ejector handles as required until the
board is disengaged.
6. After disengaging the board from the backplane, pull the board out of the slot.
7. Ensure that both extractor handle retaining screws are properly fastened.
8. Dispose of the "old" board as required observing the safety requirements indicated in
Chapter 3.1.
9. Obtain the replacement CP6003-RC board.
10. Before inserting the board in the system chassis, ensure that both the top and bottom
wedge locks are fully relaxed.
To relax the wedge lock, turn the wedge lock's screw counter-clockwise using a 2.5 mm
hex key until the screw is against the stop. The screw should turn lightly. If, when turning
the screw, perceptible resistance is encountered, it is at the stop. Do not apply more force
than necessary.
11. Ensure that both extractor handle retaining screws are properly fastened.