Zero-Point Adjustment - MICRO-EPSILON induSENSOR DTD Operating Instructions Manual

Table of Contents

Advertisement

Operation
5.4.2
D1:
Channel
G
1) Position X
must
2
be > 10 % of the
measuring range
away from X
.
Fig. 59 Menu structure for the MSC 7401 / 7802 / 7602 controllers, adjustment mode: Zero-point search
1
induSENSOR DTD / MSC7xxx

Zero-point Adjustment

D2:
E1
G
Set the output signal V
6 VDC or 12 mA is preset.
G
R
Move the measuring object to position X
output has reached V
G
Move the measuring object to position X
change the output signal V
D3:
E2
O
.
0
ENTER
O
until the
0
.
0
ENTER
O
and
1
2
with
2
D4:
Value
LED off
The LED flashes
O
and color changes
depending on the
Lights orange when
output signal
the measuring object
(green = too low
is in the electrical
red = too high).
center of the sensor.
O
The LED color
changes depending
on the position
Flashes orange when
of the measuring
the measuring object
object.
is in the electrical
center of the sensor.