8 | Brake control and temperature detection
X1C
2
4
6
1
3
5
Table 24: Assignment of the terminal block X1C
CAUTION
Specification brake/relay output
Connection
36
8 Brake control and temperature detection
PIN
1
2
3
4
5
6
8.1 Brake control
Wrong dimensioning of the brake
Brake does not release or only with delay
a) Choose the input voltage tolerance of the brake corresponding to the tolerance
of the output voltage.
b) Use auxiliary relays if necessary.
Name
Function
Output voltage (DC)
maximum output current
Others
1
X1C
2
Figure 8: Connection of a brake
Name
Notes
BR+
Brake control / output
BR-
Brake control / output
Reserved
Reserved
TA1
Temperature detection / input +
TA2
Temperature detection / input -
BR+ (X1C.1); BR- (X1C.2)
Output to supply a brake or relay.
minimum P24Vin – 2.4V
maximum P24Vin
2 A
Internal free-wheeling path; internal filter circuit;
short-circuit proof
+
U
= 24 V
_dc
-
I
= 2 A
_max
ma_dr_f6-cu-k-inst-20144795_en