Connection Of A Temperature Detection - KEB COMBIVERT G6 series Installation Manual

Housing c power 5.5...11kw
Hide thumbs Also See for COMBIVERT G6 series:
Table of Contents

Advertisement

Connection of the Power Unit
3.2.4

Connection of a temperature detection

3.2.4.1 Temperature detection terminals T1, T2
The KEB COMBIVERT G6 is delivered with a PTC evaluation. The function corresponds to
DIN EN 60947-8 and works in accordance with the following table:
Function of T1, T2
PTC or
temperature switch
The behaviour of the inverter in case of error/warning is defined with parameter
Pn.12. As standard the PTC input is deactivated. An instruction for the activation
can be found in the annex.
3.2.4.2 Terminal strip X1C temperature detection
X1C
2
1
3.2.4.3 Use of the temperature input in the PTC mode
If the temperature input is operated in the PTC mode, the user can provide all possibilities
within the resistance range specified in 3.2.4.1. This can be:
Picture 3.2.4.3
Thermal contact (NC contact) e.g. at
braking resistor
Temperature sensor (PTC) e.g. at
motor temperature detection
GB - 20
Resistance
< 750 Ω
0.75...1.65 kΩ
(reset resistance)
1.65...4 kΩ
(tripping resistance)
> 4 kΩ
No.
Name Function
1, 4 T1, T2 Connection for temperature sensor
Insertion slots to release the cage
3
2, 3
clamp terminal with screw driver
SD 0, 4x2.5 (DIN 5264)
4
5
Unlocking the terminal strip
5
Wiring examples in the PTC mode
Display ru.46
T1-T2 closed
T1-T2 closed
T1-T2 open
T1-T2 open
T1
T2
T1
T2
Error/war-
ning
x
x
Cross-section
0.2-1 mm²
AWG 24-16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert g6

Table of Contents