4 | Connection of the control
Connection
24
Terminals
Classification
Voltage output
Minimum load impedance
Notes
Connection of the analog output ANOUT
12
11
X2A.12 analog output
X2A.11 reference potential
DIN EN 61131-2
DC 0.0...10 V (corresponds to 0...100 %
output value)
1 kΩ
In the range up to 0.1 V the output value
is not linear to the output voltage.
U
=0,0...10 V
DC
Z
=1 kΩ
min