Figure 4 Rj45 Socket Front View; Table 17 Pin Assignment Rj45 Ethercat; Table 18 Function Of The Leds - KEB COMBIVERT F6 Instructions For Use Manual

Hide thumbs Also See for COMBIVERT F6:
Table of Contents

Advertisement

Connection
8
1
Figure 4: RJ45 socket front view
Light pattern NET ST LED (red/
green combination)
ma_dr_f6-cu-k-inst-20144795_en
Distributed Clocks (DC)
PIN
1
2
3
4
5
6
7
8
Table 17: PIN assignment RJ45 EtherCAT
LED / light pattern
Yellow
Green
Off
On
Flicker
Table 18: Function of the LEDs
According to ETG1300, the NET ST LED is a combination of RUN and ERROR
LED.
Status
Light pattern
init
0
Pre-Op
g-0 (grid 50 ms)
Safe-Op
g-0-0-0-0-0 (grid 200 ms)
Op
g (permanent)
error
R (permanent)
LOAD ERROR
r-0 (grid 50 ms)
Invalid configuration r-0 (grid 200 ms)
Warning limit
r-0-0-0-0-0 (grid 200 ms)
reached
Local Error
r-0-0-0-0-0 (grid 200 ms)
Process Data or Eth-
r-0-r-0-0-0-0-0 (grid 200
erCAT Watchdog
ms)
Legend
r: Red
g: Green
0: off
Fieldbus interfaces | 6
Yes, 32 Bit; minimum cycle time:
500 µs (is22=8 x tp)
250 µs (is22=4 x tp) from SW 2.8
=> Synchronous communication mode
RJ45 without supply voltage
(Viewing with Auto-Cross Over)
TX+
TX-
RX+
Reserved
Reserved
RX-
GND
GND
Function
without function
Link/Activity
Port closed
Port open; no data traffic
Port open; with data traffic
Description
Device in INITIALISATION
status; no error
Device in PRE-OPERATIONAL
status
Device in SAFE-OPERA-
TIONAL status
Device in OPERATIONAL
status; no error
Communication or device error.
Loading error during initialisa-
tion
General configuration error.
An error counter has reached
or exceeded the warning level.
Local error; Device has inde-
pendently changed status from
OPERTIONAL to SAFE-OPER-
ATIONAL. Error bit is set to "1".
A watchdog error has occurred
in the application.
The red/green signals are shif-
ted by 180°. In case of overlap-
ping, red has priority.
RX+
RX-
TX+
TX-
29