Connection

4.2.2 Digital Outputs

Specification
Connection

4.2.3 Relay output;

Specification
ma_dr_f6-cu-k-inst-20144795_en
High level (logical 1)
Internal voltage supply
2
4
6
8
10
12 14
1
3
5
7
9
Number
Name
Terminals
Type
Classification
Output voltage
Output current
Special features
Connection appliance
18
20
17
19
Number
Name
Terminals
Type
Voltage
Current
Connection of the control | 4
11 ... 30 V / 2 ... 6 mA
External voltage supply
2
4
6
16
1
3
5
11 13
15
2 (+2 more at X2B)
DO1 ... DO2
X2A.17, X2A.19
24 V high-side switch
DIN EN 61131-2
Minimum P24Vin – 3 V
Maximum P24Vin
Reference potential 0V (X2A.18 and X2A.20)
Maximum 100 mA per output (short-circuit proof)
Only ohmic load; no internal free-wheeling path
Connection external control
COM DI1 DI2
1
R1
X2A.21...X2A.23
3-pole, switching contacts
Maximum DC 30 V
0.01...1 A
8
10
12 14
16
18
20
7
9
11 13
15
17
19
+
18 20
17
19
19