9.6.2 Direct switch-off with emergency stop switch and monitoring of the
+24V
Figure 10: Direct switch-off with emergency stop switch and monitoring of the wiring
ma_dr_f6-cu-k-inst-20144795_en
wiring
Control
Safety
X2B
1 - STO1-
2 - STO1+
3 - STO2-
4 - STO2+
5 - OUT 3
6 - OUT 4
7 - 0V
8 - P24V-IN
Power
The shown circuit detects wiring faults in the area of the emergency stop
switchgear and the supply line. A possible short circuit on the primary side of the
emergency stop switchgear (ground and DC +24 V) and a short circuit on the sec-
ondary side of the device or within the wiring leads either directly or with closed
contacts to a short circuit of the supply, whereby an upstream 24 V fuse trips.
In addition to the two applications shown here with an emergency stop switching
device, other sensors (such as door switches, etc.) can be used in the same way.
Safety function STO | 9
X4A
X4B
X1A
U V W PE
X4C
X2A
X2C
X2D
43