Test no.:
21
Standard:
I
T1 (ms)
50
F1 (Hz)
360
F2 (Hz)
Fmax
Fmax = 650 Hz for Group2/A(NF)
Fmax = 800 Hz for Group3/A(WF)
T2 = 20 msec
T3 = 5 msec
Figure 9-7: Power Interrupt for Group2/A(NF) and Group3/A(WF)
VOLTAGE SURGE
This test requires 160V output voltage. If the power source is set at the low voltage range, the
high voltage range will be selected before the test starts. At the end of the test, the power
source will be switched back to the low range automatically
Seq. No.
RTCA
1
115
2
160
3
115
4
60
5
115
The output voltage will follow the sequence in Table 9-4. The above sequence will repeat itself
three times. Each repeat will start from sequence two. RTCA and Group 1 will run at 400 Hz.
Group 2 and A(NF) will run at 360 Hz and 650 Hz. Group 3 and A(WF) will run at 360Hz and
800Hz. The frequency will return to the nominal setting when the test is completed. The ← key
(backspace) will terminate the test at any time.
22
23
II
III
50
100
Fmax
360
360
Fmax
Voltage
Group 1
Group 2
115
160
115
70
115
Table 9-4: Normal VoltageSurge Sequence
24
25
IV
V
100
200
Fmax
360
360
Fmax
Group 3
115
115
160
170
115
115
70
70
115
115
26
VI
200
Fmax
360
Time
ALL
5 M inute
30msec
5 Sec.
30msec
5 Sec.
142