Ametek California Instruments MX15 Series User Manual page 13

Ac and dc power source
Table of Contents

Advertisement

Output Parameter
AC Mode
-333 Option
DC Mode &
AC+DC Mode
Standard
DC Mode &
AC+DC Mode
-333 Option
Note:
Current derates linearly from 50% of voltage range to 20% of specified current at 5% of voltage range
Current Limit mode
Repetitive Peak Current
AC Mode
Range:
Resolution:
A ccuracy:
Input:
A ccuracy:
Range:
Resolution:
A ccuracy:
MX15 Series
MX15
M X 15-1
V Lo: 90.1 A
V Hi: 45 A
M X 15-1
V Lo: 50 A
V Hi: 25 A
M X 15-1
V Lo: 45.4 A
V Hi: 22.7 A
Programmable, CC or CV mode
M X 15-1
V Lo: 300 A
V Hi: 150 A
Frequency
Standard: 16 Hz - 819.0 Hz
-LF option:
16 Hz - 500.0 Hz
-HF option:
16 Hz – 900 Hz
0.01 Hz
from 16.00 to 81.91 Hz
0.1 Hz
from 82.0 to 819.0 Hz
1 Hz
from 819 to 900 Hz
± 0.01 %
Ext. Sync Mode
Isolated TTL input for external frequency control. Requires 5V at 5 mA for logic high.
Ext. Sync to phase A with fixed Ext. Sync Frequency input:
16 Hz - 100 Hz:
< 2°
100 Hz - 500 Hz:
< 3°
> 500 Hz: < 4°
Programmable Output Impedance
R: 1 – 200 mOhm
L: 15 – 200 uH
R: 1 mOhm
L: 1 uH
10 % FS
MX30/2
M X 30/2
V Lo: 180.2 A
V Hi: 90 A
M X 30/2-1
V Lo: 100 A
V Hi: 50 A
M X 30/2-1
V Lo: 90.8 A
V Hi: 45.4 A
M X 30/2-1
V Lo: 600 A
V Hi: 300 A
N/A
N/A
N/A
MX45/3
M X 45/3
V Lo:270.3 A
V Hi: 135 A
M X 45/3-1
V Lo: 150 A
V Hi: 75 A
M X 45/3-1
V Lo: 136.2 A
V Hi: 68.1 A
M X 45/3-1
V Lo: 900 A
V Hi: 450 A
N/A
N/A
N/A
13

Advertisement

Table of Contents
loading