Sign In
Upload
Manuals
Brands
Ametek Manuals
Portable Generator
California Instruments MX45/3-1Pi-MB
Ametek California Instruments MX45/3-1Pi-MB Manuals
Manuals and User Guides for Ametek California Instruments MX45/3-1Pi-MB. We have
1
Ametek California Instruments MX45/3-1Pi-MB manual available for free PDF download: User Manual
Ametek California Instruments MX45/3-1Pi-MB User Manual (175 pages)
AC and DC Power Source
Brand:
Ametek
| Category:
Portable Generator
| Size: 4.41 MB
Table of Contents
Table of Contents
6
Introduction
10
General Description
10
Manual Organization and Format
10
Specifications
11
Electrical
11
Figure 2-1: MX Series - Voltage / Current Rating Chart - Max Rating
14
Figure 2-2: MX Series - Voltage / Current Rating Chart - Derated
14
Mechanical
18
Environmental
18
Regulatory
19
Front Panel Controls
19
Special Features and Options
19
Figure 2-3 -HF Option Voltage / Frequency Rating 300V Range
24
Figure 2-4 : -HF Option Voltage Frequency Rating 150V Range
24
Supplemental Specifications
27
Figure 2-5 MX Output Filter Option Schematic
29
Figure 2-6 : MX15 Output Noise 10 Khz - 1 Mhz
30
Figure 2-7 MX45 Output Noise 10 Khz - 1 Mhz with Optional Filter
31
Unpacking and Installation
32
Unpacking
32
Power Requirements
32
Figure 3-1: the MX15 Power Source
32
Mechanical Installation
33
AC Input Connections and Wiring
33
Figure 3-2: Location of AC Input Fuse Block and Chassis Ground Connection - Rear View, Access Panel Removed
34
Figure 3-3: MX Series AC Input Connection Diagram (Rear View)
36
AC On/Off Circuit Breaker on MX Series Front Panel
37
Table 3-1: Suggested Input Wiring Sizes for each MX Cabinet
37
Figure 3-4: Rear Panel
38
Output Connections
39
Figure 3-5: External Sense Cable Shield Connection to Chassis Ground
39
Table 3-2: Suggested Output Wiring Sizes
40
Figure 3-6: MX15-1 Output Wiring (Rear View)
41
Figure 3-7: MX30/2 or MX30/2-MB Output Wiring (Rear View)
42
Figure 3-8: Two MX's in Clock and Lock Mode Output Wiring (Rear View)
43
Figure 3-9: MX45/3 or MX45/3-MB Output Wiring (Rear View)
44
Figure 3-10: Three MX's in Clock and Lock Mode - Output Wiring (Rear View)
45
Figure 3-11: Ship Kit Terminal Block Dimensions
46
Connectors - Rear Panel
47
Table 3-3: System Interface Connectors
48
Table 3-4: Analog Interface Connector
48
Table 3-5: BNC Connectors
49
Table 3-6: External Sense Connector
49
Figure 3-12: RS232C Cable for PC Connection Wiring Diagram - MX Without USB
50
Table 3-7: RS232 Connector Pin out - MX with RS232 and USB
50
Table 3-8: RS232C Connector Pin out - MX with RS232 but no USB
50
Figure 3-13: USB Connector Pin Orientation
51
Table 3-9: USB Connector Pin out
51
Table 3-10: RJ45 LAN Connector Pin out
52
Multiple Cabinet System Configurations (Incl. -MB)
53
Figure 3-14: Multi-Cabinet DIP Switch Location and Setting
53
Multiple Cabinet Power Up/Down Procedures
54
Clock and Lock Configurations
55
Table 3-11: Clock and Lock Configuration Settings
55
Table 3-12: Clock and Lock Initialization Settings
56
Basic Initial Functional Test
57
Figure 3-15: Functional Test Setup
58
Remote Inhibit / Remote Shutdown
59
Junction Box Accessory
60
Figure 3-16: 7003-416-1 Output Junction Box
60
Output Filter Box Accessory
61
Figure 3-17: 7003-424-1 Output Noise Filter Box
61
Front Panel Operation
62
Tour of the Front Panel
62
Figure 4-1: Shuttle Knob
64
Figure 4-2: FUNCTION Keypad
65
Figure 4-3: Measurement Screen
66
Menu Structure
67
Table 4-1: Menu Tree
70
Figure 4-4: PROGRAM Menus
71
Figure 4-5: CONTROL Menus
73
Figure 4-6: MEASUREMENT Screen
75
Output Programming
88
Waveform Management [1Pi Controller Only]
90
Figure 4-7: Selecting a Waveform
90
Figure 4-8: Custom Waveform Creation with GUI Program
91
Figure 4-9: Waveform Crest Factor Affects Max. Rms Voltage
92
Standard Measurements
94
Advanced Measurements [1Pi Controller Only]
96
Transient Programming
97
Figure 4-10: Pulse Transients
98
Figure 4-11: List Transients
99
Figure 4-12: Sample Transient Output Sequence
100
Table 4-2: Sample Transient List
100
Figure 4-13: Switching Waveforms in a Transient List
101
Figure 4-14: TRANSIENT Menu
102
Principle of Operation
103
General
103
Overall Description
103
Figure 5-1: MX Series Functional Block Diagram
103
Controller Assembly
105
Figure 5-2: MX Series Detailed Block Diagram
106
Figure 5-3: Power Module Detailed Block Diagram
107
System Interface Board
108
Current / Voltage Sensor Board
108
Low Voltage Power Supply
108
Power Module
109
Figure 5-4: Power Module Layout
109
Figure 5-5: Amplifier Board Layout
111
Calibration
114
Recommended Calibration Equipment
114
Front Panel Calibration Screens
115
Figure 6-1: Calibration Setup (Rear View)
115
Routine Measurement Calibration
116
Table 6-1: Calibration Load Values
116
Table 6-2: Measurement Calibration Table
117
Routine Output Calibration
118
Table 6-3: Output Calibration Table - MX15 Series
118
Non-Routine Calibration
119
Table 6-4: Programmable Z Adjustment Pots
121
Table 6-5: Formulas to Calculate R and L
121
Service
122
Cleaning
122
General
122
Basic Operation
122
Table 7-1: Basic Symptoms
122
Advanced Troubleshooting
124
Factory Assistance
126
Fuses
127
Firmware Updates
127
Table 7-2: MX Fuse Ratings
127
Table 7-3: Flash Download Messages
129
Top Assembly Replaceable Parts
130
Table 8-1: Replaceable Parts
131
Table 8-2: Fuses
132
Options
133
Introduction
133
Option -HV: Additional AC Voltage Range
133
Option -160: RTCA/DO-160 Tests
134
Figure 9-1: Application Menu
135
Figure 9-2: DO160 Main Menus
136
Figure 9-3: Normal State Screens
136
Table 9-1: Normal Voltage and Frequency Minimum
137
Table 9-2: Normal Voltage and Frequency Maximum
137
Table 9-3: Airbus Mode Voltage Modulation
138
Figure 9-4: Voltage Modulation - Frequency Characteristics
139
Figure 9-5: Frequency Modulation
140
Figure 9-6: Power Interrupt
141
Figure 9-7: Power Interrupt for Group2/A(NF) and Group3/A(WF)
142
Table 9-4: Normal Voltagesurge Sequence
142
Table 9-5: Normal Frequency Transient Sequence
143
Table 9-6: Normal Frequency Variation Sequence
143
Figure 9-8: Emergency Screens
144
Table 9-7: Emergency Voltage and Frequency Minimum
144
Table 9-8: Emergency Voltage and Frequency Maximum
144
Figure 9-9: Abnormal Screen
145
Table 9-9: Abnormal Voltage Minimum
145
Table 9-10: Abnormal Voltage Maximum
145
Table 9-11: Abnormal Frequency Transient
147
Option -704: Milstd704 Tests
148
Figure 9-10: Applications Menu
150
Figure 9-11: MIL704 Menu
150
Figure 9-12: Steady State Menu
151
Table 9-12: Steady State Voltage
151
Table 9-13: Steady State Frequency
152
Table 9-14: Frequency Modulation
152
Figure 9-13: Emergency Menu
154
Figure 9-14: Abnormal Screens
155
Table 9-15: Abnormal over Frequency
156
Table 9-16: Abnormal under Frequency
156
Figure 9-15: MIL704 DC Menu
157
Figure 9-16: Steady State DC
157
Figure 9-17: Transient Menu
158
Figure 9-18: Abnormal Test Screen
159
Figure 9-19: Emergency Test
160
Option -ABD: Airbus ABD0100.1.8 Test
161
Option -787: Boeing B787-0147 Test
161
Option -WHM: Watt Hour Measurement
162
Figure 9-20: Watt-Hour Meter Screen
162
Figure 9-21: WH-Meter Screen with Function Active
162
Option -411: IEC 61000-4-11 Voltage Dips and Interruptions
163
Option -413: IEC 61000-4-13 Interharmonics Test
164
Figure 9-22: APPLICATION SCREEN
165
Figure 9-23: INTERHARMONICS SCREENS
165
Figure 9-24: REGENERATE CONTROL Screen
167
Error Messages
169
Table 10-1: Error Messages
172
Index
173
Advertisement
Advertisement
Related Products
Ametek California Instruments MX45/3-1
Ametek California Instruments MX45/3-1Pi
Ametek MX Series
Ametek MX22.5-1
Ametek California Instruments MX15 Series
Ametek California Instruments MX15-1P
Ametek California Instruments MX15-1Pi
Ametek California Instruments MX30/2-1
Ametek California Instruments MX30/2-1Pi-MB
Ametek California Instruments MX30/2-1Pi
Ametek Categories
Measuring Instruments
Test Equipment
Power Supply
Controller
Laboratory Equipment
More Ametek Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL