2.1.7
Unit Protection
Input Over current:
Input Over voltage:
Input Over voltage
Transients:
Output Over current:
Output Short Circuit:
Over temperature:

2.2 Mechanical

Parameter
Dimensions:
(for each M X chassis)
Unit W eight:
(for each M X chassis)
M aterial:
Finish:
Cooling:
Internal Construction:
Rear Panel
Connections:

2.3 Environmental

Parameter
Operating Temp:
Storage Temp:
A ltitude:
Relative Humidity:
18
In-line fast acting fuses. Check fuse rating in Service and Maintenance
section. Ratings will depend on AC input configuration settings.
Circuit breaker for LV supply.
Automatic shutdown.
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Adjustable level constant current mode with programmable set point.
Peak and RMS current limit.
Automatic shutdown.
Height:
31.75"
806 mm
W idth:
24"
610 mm
Depth:
28"
711 mm
Net:
600 lbs / 272 K g
Shipping: 681 lbs / 309 K g
Steel chassis with aluminum panels and covers.
Light textured painted external surfaces.
Panels semi-gloss polyurethane color no. 26440 (medium gray)
Fan cooled with air intake on the front and exhaust to the rear.
Fans:
2 x 225CFM .
A ir displacement
7.5 Cu Ft/sec. M ax.
M odular sub assemblies.
(See section 3 for description of connections)
Cable entry and strain relieve for A C input wiring
Cable entry and strain relieve for output wiring
External sense terminal block (Remote voltage sense)
System interface (2x)
Clock and Lock BNC's (requires -LK M or -LK S options)
RS232, USB, GPIB, LA N (option)
Trigger In BNC
Trigger Out BNC
Function Strobe BNC
Output Status
0° to +40° C. (Except in CP mode).
+32° to +104° F.
-40° to +85 °C.
-40° to +185° F.
< 2000 meters
0-95 % RA H, non-condensing maximum for temperatures up to 31°C decreasing
linearly to 50% at 40°C.