Ametek California Instruments MX15 Series User Manual page 81

Ac and dc power source
Table of Contents

Advertisement

4.2.9
CONFIGURATION Menu
The configuration menu may be used to configure various aspects of the instrument such as the
serial port (including USB and LAN), IEEE-488/GPIB address and the power-on settings of the
supply.
ENTRY
A DDRESS
BA UD RA TE
PON STA TE
LA Network
MX15 Series
DESCRIPTION
0 - 31
Sets the selected IEEE / GPIB bus address for the optional
IEEE/GPIB interface.
Factory default is address 1. The shuttle knob or the keypad
can be used to set a value from 0 through 31. Do not use
address 0 as this address is typically reserved for the GPIB
controller.
9600
Sets the baud rate for the RS232 communications port.
19200
Factory default is 38400 baud. A vailable settings are 9600
38400
through 115200 baud.
57600
The same setting is used for USB and LA N modes. For use with
115200
either USB or LA N, the baud rate in this screen must be set to
230400
460800.
460800
Note: The shuttle knob can be used to scroll through these
selections.
REG0
Determined power on state. This setting selects either non-
RST
volatile REG0 to be recalled automatically at power-on or
factory default (RST). Factory default is RST, which recalls the
factory settings. See below.
Factory default settings are:
Output relay
V oltage Range
M ode
A C
V oltage
0 V rms
Frequency 60 Hz
Note that to use REG0 for power-on default, the contents of
the register must be programmed first. See section 4.2.8. If an
empty register is selected, the power source will revert back to
RST (factory setting).
LA N
If the –LA N option is installed; pressing Enter while the cursor
is on the LA Network entry provides access to the LA N interface
setting screens listed below.
IP A ddress
Displays the IP address setting. This value can be changed by
pressing the SET key and entering a new value from the
keypad. Use the numeric data pad to enter each field. To move
between the four fields, use the decimal point key on the
keypad.
To set a fixed IP address, press SET and enter the desired IP
Open
Low
81