Table 9-15: Abnormal Over Frequency; Table 9-16: Abnormal Under Frequency - Ametek California Instruments MX15 Series User Manual

Ac and dc power source
Table of Contents

Advertisement

The Voltage gradually decays with time to 122 volt by the following equation:
Stay at 122V for 8 seconds before returning to 115V.
Note: Prior to the test, a voltage range change may take place if the power source is set for the
low voltage range. This will cause the EUT to lose power momentarily. If this is not acceptable,
the power source must be left in high range at all times.
The ← key (backspace) will terminate the test at any time.
UNDER VOLTAGE
This test will change the output voltage for the selected phase in the following sequence:
For 400Hz and VFREQ:
0V for 7 seconds.
100V for 93 seconds.
For 60Hz only
0V for 2 seconds.
100V for 8 seconds.
The ← key (backspace) will terminate the test at any time.
OVER FREQUENCY
This test will change the output frequency in the sequence shown in Table 9-15 before returning
to the steady state frequency.
The ← key (backspace) will terminate the test at any time.
Revision
Seq1
Seq2
After this sequence, a 5 second delay will be inserted at the nominal test frequency. The ← key
(backspace) will terminate the test at any time.
UNDER FREQUENCY
This test will change the output frequency in the sequence shown in Table 9-16 before returning
to steady state frequency.
The ← key (backspace) will terminate the test at any time.
Revision
Seq1
Seq2
V = 121.7 + 0.583/t. For 0.00334
D
FREQ
Time
FREQ
480Hz
5sec.
480Hz
420Hz
5sec
420Hz

Table 9-15: Abnormal Over Frequency

D
FREQ
Time
FREQ
0
5sec.
0Hz
375Hz
5sec
380Hz

Table 9-16: Abnormal Under Frequency

t
E
F
Time
FREQ
5sec.
480Hz
9sec
420Hz
E
F
Time
FREQ
7sec.
0Hz
7sec
380Hz
1.947
F 60Hz only
TIME
FREQ
TIME
5sec
61Hz
7sec
5sec
60.5Hz
8sec
F 60Hz only
TIME
FREQ
TIME
7sec
0Hz
7sec
3sec
59.5Hz
8sec
156