Controller Features
controller in this configuration. One unit acts as the master and provides the
reference clock to the auxiliary units.
Programmable controller front panel assembly.
Standard output relay feature to isolate power source from the load.
The output relay can be used to quickly disconnect the load. A n amber status
indicator displays the status of the output relay.
Firmware Options
M il Std 704D & E test firmware.
M il Std 704A , B, C, & F test software (refer to A vionics Software M anual P/N 4994-971
for details).
Note: Requires use of V irtual Panels W indows application software provided on CD
ROM CIC496.
RTCA /DO-160D test firmware
RTCA /DO-160E test software (refer to A vionics Software M anual P/N 4994-971 for
details)..
Note: Requires use of V irtual Panels W indows application software provided on CD
ROM CIC496.
IEC 61000-4-11 V oltage Dips and Interruptions Test firmware. Supported over remote
control interface only.
IEC 61000-4-13 Interharmonics Test Firmware. Supported over remote control
interface only.
Boeing 787 Test software (refer to A vionics Software M anual P/N 4994-971 for
details)
Note: Requires use of V irtual Panels GUI W indows application software provided on
CD ROM CIC496.
A irbus A BD0100.1.8 Test software (refer to A vionics Software M anual P/N 4994-971
for details).
Note: Requires use of V irtual Panels W indows application software provided on CD
ROM CIC496.
W att Hour M easurements (A ccuracy and Resolution. See Sec. 2.6.5.)
Output Voltage Range Options
Replaces 150 / 300A C and 200 / 400DC ranges with 166 / 333A C and 220 / 440DC
A dds 400 V A C only output range.
A dds customer specified A C only output range. Contact factory for details.
Misc. Options
Emergency Shut off switch. This option key lock push button is installed on the front
panel of the master M X if ordered with the M X system. W hen pushed in, the main A C
contactor is opened disconnecting the A C input power to the M X input transformer.
Note that the controller (and LCD display) will still be powered up but no power is
available to the amplifiers and there will be no output power either. The controller
runs off the LV supply, which must be turned off with the front panel breaker.
A fter the ES has been pushed, the provided key will be required to release it. Once the
ES button has been released, the M X
circuit breaker and turned back on to start up again.
Note: Do not misplace the 2 keys provided, as no duplicates are available from CI. If
lost, the ES switch must be replaced. In that case, contact A M ETEK Programmable
Power customer service.
(service@programmablepower.com
M ulti-box Option. Provides additional controllers in A uxiliary units of multi-cabinet
configurations (M X 30/2, M X 45/3) to allow individual M X 15 units to be used stand-
alone.
Limits maximum output frequency to 500 Hz.
Increases maximum output frequency to 900 Hz.